Maxwell‐compensated design of asymmetric gradient waveforms for tensor‐valued diffusion encoding

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Constrained optimization of gradient waveforms for generalized diffusion encoding.

Diffusion MRI is a useful probe of tissue microstructure. The conventional diffusion encoding sequence, the single pulsed field gradient, has recently been challenged as more general gradient waveforms have been introduced. Out of these, we focus on q-space trajectory imaging, which generalizes the scalar b-value to a tensor valued entity. To take full advantage of its capabilities, it is imper...

متن کامل

Optimal diffusion-gradient waveforms for measuring axon diameter

Introduction: Measuring microstructure parameters of brain tissue, such as axon radius, in vivo is a challenge in diffusion MRI. Current approaches typically use pulsed-gradient spin-echo (PGSE) [1] or stimulated-echo (STEAM) [2] sequences, both of which use a rectangular diffusion-gradient pulse. However other shapes of diffusion-gradient pulses such as oscillating [3] or chirped [4] may provi...

متن کامل

Computational Diffusion MRI: Optimal Gradient Encoding Schemes

Diffusion-weighted magnetic resonance imaging (dMRI) is a non-invasive structural imaging technique that provides information about tissue micro-structures. Quantitative measures derived from dMRI reflect pathological and developmental changes in living tissues such as human brain. Such parameters are increasingly used in diagnostic and prognostic procedures and this has motivated several studi...

متن کامل

investigating the feasibility of a proposed model for geometric design of deployable arch structures

deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...

Optimized gradient waveforms for spiral scanning.

Spiral scanning gradient waveforms can be optimized with respect to blurring from off-resonance effects by minimizing the readout time. This is achieved by maximizing the gradient amplitude during the scan so that the edge of k-space is reached as quickly as possible. Gradient hardware constraints are incorporated by considering a circuit model for the gradient coil and amplifier. The optimized...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2019

ISSN: 0740-3194,1522-2594

DOI: 10.1002/mrm.27828