Measurement-based Static Load Modeling Using the PMU data Installed on the University Load
نویسندگان
چکیده
منابع مشابه
Measurement-based Static Load Modeling Using the PMU data Installed on the University Load
Load modeling has a significant influence on power system analysis and control. In recent years, measurement-based load modeling has been widely practiced. In the load modeling algorithm, the model structure is determined and the parameters of the established model are estimated. For parameter estimation, least-squares optimization method is applied. The model parameters are estimated so that t...
متن کاملthe effect of lexically based language teaching (lblt) on vocabulary learning among iranian pre-university students
هدف پژوهش حاضر بررسی تاثیر روش تدریس واژگانی (واژه-محور) بر یادگیری لغات در بین دانش آموزان دوره پیش دانشگاهی است. بدین منظور دو گروه از دانش آموزان دوره پیش دانشگاهی (شصت نفر) که در سال تحصیلی 1389 در شهرستان نور آباد استان لرستان مشغول به تحصیل بودند انتخاب شده و به صورت قراردادی گروه آزمایش و گواه در نظر گرفته شدند. در ابتدا به منظور اطمینان یافتن از میزان همگن بودن دو گروه از دانش واژگان، آ...
15 صفحه اولEmbedded Crack Identification in Beam-Column Structures Under Axial Load Using an Efficient Static Data Based Indicator
A triangular model base on an investigation which has done by Sinha et al. has been developed for evaluating embedded crack localization in beam-column structures. In the assessment of this member’s behavior, the effects of displacement slope are necessary. In order to propose a crack localization method for embedded crack, an efficient static data based indicator is proposed for this crack in ...
متن کاملAggregate Static Power Load Modeling in Coalmine
-In order to overcome the defects of the traditional static load modeling in coalmine, a new modeling method is proposed in this paper. First, a new clustering method based on improved PSO algorithm is presented to classify the load data in order to reduce the number of load model before modeling. Second, RBF neural network based on improved PSO algorithm is put forward to establish aggregate l...
متن کاملOn the confusion between static load level and static task.
Electromyography (EMG) is widely used to evaluate muscle activity. EMG can indicate which muscles are active and the relationship between a level of activity and the worker's capacity. Properly employed, EMG assists in evaluating the relative risks of alternative working conditions. Articles reporting EMG results are often used by ergonomics practitioners as guidance in job design. As such, the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Electrical Engineering and Technology
سال: 2012
ISSN: 1975-0102
DOI: 10.5370/jeet.2012.7.5.653