Measurement delay associated with the Guardian® RT continuous glucose monitoring system

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement delay associated with the Guardian® RT continuous glucose monitoring system

AIMS Using compartment modelling, we assessed the time delay between blood glucose and sensor glucose measured by the Guardian RT continuous glucose monitoring system in young subjects with Type 1 diabetes (T1D). METHODS Twelve children and adolescents with T1D treated by continuous subcutaneous insulin infusion (male/female 7/5; age 13.1 +/- 4.2 years; body mass index 21.9 +/- 4.3 kg/m(2); m...

متن کامل

Toward a Continuous Intravascular Glucose Monitoring System

Proof-of-concept studies that display the potential of using a glucose-sensitive hydrogel as a continuous glucose sensor are presented. The swelling ratio, porosity, and diffusivity of the hydrogel increased with glucose concentration. In glucose solutions of 50, 100, 200, and 300 mg/dL, the hydrogel swelling ratios were 4.9, 12.3, 15.9, and 21.7, respectively, and the swelling was reversible. ...

متن کامل

Continuous glucose monitoring system for congenital hyperinsulinemia.

Blood glucose monitoring is a way of testing the concentration of glucose in the blood. The most recent advance is the development of continuous glucose monitoring system (CGMS) which gives 24 hour trend of blood sugar levels thus helping both the patient and the physician in achieving better glycemic control. CGMS in pediatric population is generally used for those on insulin pumps and those w...

متن کامل

Low Noise Measurement of Photocurrent for Continuous Glucose Monitoring - Low Noise Measurement System Enables Continuous Monitoring of Glucose in Subcutaneous Interstitial Fluid

The purpose of this work is mainly to manufacture several anatomical models in a polymeric material – polydimensiloxane (PDMS) to study the blood flow through a carotid artery bifurcation. Over the last few decades, research has been shown that the geometry of the carotid artery is closely related to the development of serious cardiovascular diseases. Hence, there is a considerable interest in ...

متن کامل

Continuous tissue glucose monitoring correlates with measurement of intermittent capillary glucose in patients with distributive shock.

BACKGROUND Intermittent glycemic measurements in patients admitted to the intensive care unit (ICU) can result in episodes of severe hypoglycemia or in a poor control of glycemia range. We designed a study to assess accuracy and reliability of continuous monitoring of tissue glucose for patients with distributive shock. METHODS Consecutive patients admitted to the ICU with a diagnosis of dist...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Diabetic Medicine

سال: 2009

ISSN: 0742-3071

DOI: 10.1111/j.1464-5491.2009.02887.x