MEASUREMENT OF CARDIAC OUTPUT IN ANAESTHETIZED ANIMALS BY A THERMO-DILUTION METHOD
نویسندگان
چکیده
منابع مشابه
Fiberoptic-Dye Dilution Method for Measurement of Cardiac Output
A new method for the measurement of cardiac output has been tested in 69 patients undergoing catheterization of the right and left sides of the heart. It is based on the recently described fiberoptic hemoreflection method. In order to verify the validity of these measurements, correlations with stroke indices determined by the Fick principle and by biplane angiocardiography were also carried ou...
متن کاملA preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs
BACKGROUND Haemodynamic variations normally occur in anaesthetized animals, in relation to the animal status, administered drugs, sympathetic and parasympathetic tone, fluid therapy and surgical stimulus. The possibility to measure some cardiovascular parameters, such as cardiac output (CO), during anaesthesia would be beneficial for both the anaesthesia management and its outcome. New techniqu...
متن کاملCardiac Output by the Dilution Method without Arterial Sampling
The selection of an external site for a radioisotope determination of cardiac output is discussed with respect to satisfying the analytical conditions of the Stewart-Hamilton dilution equation. Examples of both single-chamber and multichamber recording are illustrated, along with a discussion of the difficulties of curve calibration and extrapola. tion from multiple sites. The development of a ...
متن کاملIndicator-dilution measurement of cardiac output with dissolved hydrogen.
Dissolved HL has been used as an indicator for measuring cardiac output by the techniques of constant-rate injection and sudden, single injection indicator dilution. Because of its low solubility, H2 is eliminated essentially quantitatively in the lungs and recirculates negligibly. The constant-rate injection technique involves the gas chromatographic measurement of pulmonary (or systemic) arte...
متن کاملNew method of cardiac output measurement using ultrasound velocity dilution in rats.
The aim of this study was to validate a new technique for the measurement of cardiac output (CO) based on ultrasound and dilution (COUD) in anesthetized rats. A transit time ultrasound (TTU) probe was placed around the rat carotid artery, and ultrasound velocity dilution curves were generated on intravenous injections of saline. CO by COUD were calculated from the dilution curves for normal and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Quarterly Journal of Experimental Physiology and Cognate Medical Sciences
سال: 1954
ISSN: 0033-5541
DOI: 10.1113/expphysiol.1954.sp001067