Measurement of dental implant stability by resonance frequency analysis: a study
نویسندگان
چکیده
منابع مشابه
Measurement of dental implant stability by resonance frequency analysis: a review of the literature.
Dental implant treatment is an excellent option for prosthetic restoration that is associated with high success rates. Implant stability is essential for a good outcome. The clinical assessment of osseointegration is based on mechanical stability rather than histological criteria, considering primary stability (absence of mobility in bone bed after implant insertion) and secondary stability (bo...
متن کاملResonance frequency analysis of implant stability in augmented and non-augmented sinus sites
Background and aim: Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...
متن کاملInvestigation of Initial Implant Stability with Different Dental Implant Designs. A Pilot Study in Pig Ribs Using Resonance Frequency Analysis
Linish Vidyasagar B.D.S., MSc (Helsinki), Dip. Prosth., Department of Prosthodontics, Faculty of Dentistry, Riga Stradina University, Riga, Latvia. Girts Salms M.D., D.D.S., Lecturer at Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Riga Stradina University, Riga, Latvia. Peteris Apse D.D.S., MSc (Toronto), Dr. habil med. (Latvia), professor, Department of Prosthodontics, F...
متن کاملMeasurement of Primary and Secondary Stability of Dental Implants by Resonance Frequency Analysis Method in Mandible
Background. There is no doubt that the success of the dental implants depends on the stability. The aim of this work was to measure the stability of dental implants prior to loading the implants, using a resonance frequency analysis (RFA) by Osstell mentor device. Methods. Ten healthy and nonsmoker patients over 40 years of age with at least six months of complete or partial edentulous mouth re...
متن کاملImplant stability evaluation by resonance frequency analysis in the fit lock technique. A clinical study.
Surgical procedures for the application of implants in the lateral-superior sectors are affected by the availability of the residual bone. When this condition is lower than 5 mm it is recommended that techniques involving two therapeutic phases, a reconstructive and an applicative one, as reported in the international literature, are adopted. The authors propose here a new method with the poten...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Oral and Maxillofacial Surgery
سال: 2017
ISSN: 0901-5027
DOI: 10.1016/j.ijom.2017.02.340