Measurement of direct bilirubin by use of bilirubin oxidase.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of direct bilirubin by use of bilirubin oxidase.

We developed an enzymatic method for measuring direct-reacting bilirubin (DBIL) in serum. At pH 4.5, bilirubin oxidase (BOX) oxidizes mono-conjugated bilirubin, di-conjugated bilirubin, and most of the delta-bilirubin to biliverdin. The resulting decrease in absorbance at 460 nm is linearly related to the concentration of DBIL in serum. Mean DBIL values in the 51 patients' sera examined by the ...

متن کامل

Measurement of total bilirubin by use of bilirubin oxidase.

We used an enzymatic method for measuring total bilirubin in serum. Results by this method varied linearly with bilirubin concentrations to at least 300 mg/L. The day-to-day precision (CV) of the method ranged from less than 1% to about 11% at bilirubin concentrations of 183 and 12 mg/L, respectively. Commonly used anticoagulants, serum preparation materials, and selected drugs had no effect on...

متن کامل

Direct bilirubin higher than total bilirubin?

Both total and direct bilirubin measure the formation of azobilirubin, which is detected at 570/660 nm. The total bilirubin reaction contains surfactant and caffeine, which solubilize “indirect” bilirubin and accelerate the reaction (1). Direct bilirubin is a component of total bilirubin and therefore should always be smaller in value. The presence of a monoclonal immunoglobulin (2220mg/dL) fal...

متن کامل

Determination of conjugated and total bilirubin in serum of neonates, with use of bilirubin oxidase.

A new, simple, and rapid assay for conjugated bilirubin that does not require serum-matrix standards was developed by using the enzyme bilirubin oxidase (EC 1.3.3.5). This procedure can also be modified to measure total bilirubin. Measurements from these assays were compared with results obtained with the Sigma 605 (Jendrassik-Gróf method), Sigma 550/551 (Walters-Gerarde method), and Kodak Ekta...

متن کامل

Light has a greater effect on direct bilirubin measured by the bilirubin oxidase method than by the diazo method.

We compared the effect of light on direct-reacting bilirubin (DBIL) measurement by the bilirubin oxidase (EC 1.3.3.5; BOX) method and by the Jendrassik-Gróf diazo method. DBIL concentrations determined by the BOX method in the sera of hyperbilirubinemic infants treated with phototherapy yielded falsely higher values than those by the direct diazo method. A similar tendency was noted when DBIL c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Chemistry

سال: 1987

ISSN: 0009-9147,1530-8561

DOI: 10.1093/clinchem/33.8.1349