Measurement of k0 values for europium, lutetium and iridium at FRM II with a very well thermalized neutron spectrum

نویسندگان

چکیده

Abstract The k 0 values of 6 non-1/ v nuclides ( 152 Eu, 152m 154 177 Lu, 192 Ir and 194 Ir) were determined using the extended Høgdahl formalism at research reactor FRM II with very high f values. Standards irradiated in 4 channels different local temperatures between 40 °C 55 measured temperature sensitive irreversible labels. A good agreement recommended was found for Eu Lu original g T n ) factors by Gryntakis, however, this work 7% higher. New also Van Sluijs. Differences up to 6% isotopes compared could be confirmed = 1. theoretical calculated new nuclear data. They are less than present showed a similar trend. influence on determination investigated.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advanced Neutron Instrumentation at FRM-II

The construction of the new German high flux neutron source FRM-II is finished and FRM-II is waiting for its licence to start nuclear operation. With the beginning of the routine operation 22 instruments will be in action, including 5 irradiation facilities and 17 beam tube instruments, most of them use neutron scattering techniques. Additional instruments are under construction. Some of these ...

متن کامل

A next generation measurement of the electric dipole moment of the neutron at the FRM II

I. Altarev(), S. Chesnevskaya(), W. Feldmeier(), P. Fierlinger(), A. Frei(), E. Gutsmiedl(), F. Kuchler(), P. Link(), T. Lins(), M. Marino(), S. Paul(), G. Petzoldt(), A. Pichlmaier(), R. Stoepler(), S. Stuiber(), B. Taubenheim() () Physikdepartment Technische Universität München and Excellence-Cluster ’Universe’ () Technische Universität München, Forschungsneutronenquelle Heinz Maier-Leibnitz ...

متن کامل

SPHERES, Jülich's high-flux neutron backscattering spectrometer at FRM II.

SPHERES is a third-generation neutron backscattering spectrometer, located at the 20 MW German neutron source FRM II and operated by the Jülich Centre for Neutron Science. It offers an energy resolution (fwhm) better than 0.65 μeV, a dynamic range of ± 31 μeV, and a signal-to-noise ratio of up to 1750:1.

متن کامل

The New German Neutron Source Frm Ii

The new research reactor of the Technische Universität München will provide the German needs of neutrons for the beginning of the next century. High intensities of thermal neutrons are provided by a particular densely packed core of highly enriched uranium and are extracted by 12 beam apertures. The low thermal power of 20 MW allows the positioning of a D2 cold source at a maximum of the therma...

متن کامل

designing and validating a textbook evaluation questionnaire for reading comprehension ii and exploring its relationship with achievement

در هر برنامه آموزشی، مهم ترین فاکتور موثر بر موفقیت دانش آموزان کتاب درسی است (مک دونو و شاو 2003). در حقیقت ، کتاب قلب آموزش زبان انگلیسی است( شلدن 1988). به دلیل اهمیت والای کتاب به عنوان عنصر ضروری کلاس های آموزش زبان ، کتب باید به دقت ارزیابی و انتخاب شده تا از هرگونه تاثیر منفی بر دانش آموزان جلوگیری شود( لیتز). این تحقیق با طراحی پرسش نامه ارزیابی کتاب که فرصت ارزیابی معتبر را به اساتید د...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Radioanalytical and Nuclear Chemistry

سال: 2021

ISSN: ['0236-5731', '1588-2780']

DOI: https://doi.org/10.1007/s10967-020-07500-2