Measurement of Rectal Dose during HDR Brachytherapy using the new MOSkinDosimeter
نویسندگان
چکیده
منابع مشابه
High dose rate (HDR) brachytherapy quality assurance: a practical guide
The widespread adoption of high dose rate brachytherapy with its inherent dangers necessitates adoption of appropriate quality assurance measures to minimize risks to both patients and medical staff. This paper is aimed at assisting someone who is establishing a new program or revising one already in place into adhere to the recently issued Nuclear Regulatory Commission (USA) regulations and th...
متن کاملDose correction in lung for HDR breast brachytherapy
PURPOSE To evaluate the dosimetric impact of lung tissue in Ir-192 APBI. MATERIAL AND METHODS In a 40 × 40 × 40 cm(3) water tank, an Accelerated Partial Breast Irradiation (APBI) brachytherapy balloon inflated to 4 cm diameter was situated directly below the center of a 30 × 30 × 1 cm(3) solid water slab. Nine cm of solid water was stacked above the 1 cm base. A parallel plate ion chamber was...
متن کاملDose optimization of breast balloon brachytherapy using a stepping Ir192 HDR source
There is a considerable underdosage (11%-13%) of PTV due to anisotropy of a stationary source in breast balloon brachytherapy. We improved the PTV coverage by varying multiple dwell positions and weights. We assumed that the diameter of spherical balloons varied from 4.0 cm to 5.0 cm, that the PTV was a 1-cm thick spherical shell over the balloon (reduced by the small portion occupied by the ca...
متن کاملOptimization of HDR brachytherapy dose distributions using linear programming with penalty costs.
Prostate cancer is increasingly treated with high-dose-rate (HDR) brachytherapy, a type of radiotherapy in which a radioactive source is guided through catheters temporarily implanted in the prostate. Clinicians must set dwell times for the source inside the catheters so the resulting dose distribution minimizes deviation from dose prescriptions that conform to patient-specific anatomy. The pri...
متن کاملImpact of using linear optimization models in dose planning for HDR brachytherapy.
PURPOSE Dose plans generated with optimization models hitherto used in high-dose-rate (HDR) brachytherapy have shown a tendency to yield longer dwell times than manually optimized plans. Concern has been raised for the corresponding undesired hot spots, and various methods to mitigate these have been developed. The hypotheses upon this work is based are (a) that one cause for the long dwell tim...