Measurement of Regional Cerebral Blood Volume by Photoelectric Method
نویسندگان
چکیده
منابع مشابه
MR measurement of regional relative cerebral blood volume in epilepsy.
The purpose of this study was to evaluate the utility of magnetic resonance (MR) relative cerebral blood volume (rCBV) maps for studying regional hemodynamic changes in interictal and ictal epilepsy patients. Ten epilepsy patients were examined on a 1.5 T MR system. Nine patients were investigated interictally and one patient ictally. In the nine interictal patients, the dynamic plane was defin...
متن کاملImproved Method for Noninvasive Measurement of Regional Cerebral Blood Flow
A clinical method for noninvasive measurement of regional cerebral blood flow (rCBF) and blood volume (rCBV) is described, based on Obrist's 10 minute, desaturation method after 1 minute inhalation of Xe. Sixteen collimated probes are placed over both hemispheres and brain stem-cerebellar regions. End-tidal Xe curves are used for correction of recirculation. KEV discriminators are set to record...
متن کاملComparison of static and dynamic MRI techniques for the measurement of regional cerebral blood volume.
Two different acquisition and processing strategies to determine the regional cerebral blood volume (rCBV) with magnetic resonance imaging (MRI) are compared. The first method is based on the acquisition of the signal time course during a bolus administration of a contrast agent (dynamic method). The second method evaluates signal changes before and after the contrast agent injection (static me...
متن کاملThe effects of arterial blood pressure on the regional cerebral blood volume by X-ray fluorescence.
The Effects of A rterial Blood Pressure on the Regional Cerebral Blood Volume by X-Ray Fluorescence • Cerebral blood flow (CBF) remains constant over a wide range of arterial blood pressure. This is thought to be accomplished by changes in the diameter, and therefore the volume, of the cerebral resistance vessels. To test this hypothesis, regional cerebral blood volume (rCBV) was measured in vi...
متن کاملAssessment of cerebral blood flow by means of blood-flow-volume measurement.
of Blood-Flow-Volume Measurement To the Editor: With great interest we read in Stroke that a working group around Soustiel1 compared cerebral blood flow (CBF) as measured by xenon clearance technique with blood-flow-volume (BFV) measurements from the internal carotid artery (ICA). Soustiel et al found well-correlated data, ie, correlation coefficients 0.75, in a total of 77 measurements. As a c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Neurologia medico-chirurgica
سال: 1978
ISSN: 0470-8105,1349-8029
DOI: 10.2176/nmc.18pt2.655