Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and the Rutland-Patlak plot technique

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of glomerular filtration rate by dynamic contrast‐enhanced magnetic resonance imaging using a subject‐specific two‐compartment model

Measuring glomerular filtration rate (GFR) by dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) as part of standard of care clinicalMRIexams (e.g., in pediatric solid tumor patients) has the potential to reduce diagnostic burden. However, enthusiasm for this relatively newGFRtest may be curbed by the limited amount of cross-calibration studies with referenceGFRtechniques and the ...

متن کامل

The measurement of glomerular filtration rate in single nephrons of the rat kidney.

Perlhaps nowlhere in the broad spectrum of present-day renal plhysiology studied with micropunctuire teclhniques lhas there occurred a greater nor more damaging erosion of confi(lence in the interpretation of results than in the area pertaining to the measurement of glomerular filtration rate (GFR) in single neplhrons. In large part, this decline in confidence can be traced to a recent series o...

متن کامل

Evaluation of Glomerular Filtration Rate Estimating Formulas in Diabetic Patients with Chronic Kidney Disease

Objective: Measurement of glomerular filtration rate (GFR) is the best determinant in assessment of kidney function for diagnostic and therapeutic purposes. As extremely accurate methods of GFR measurement (i.e. Inulin clearance) are expensive and Time-consuming and due to limitations of the 24 hour urine collection method, some formula have been developed for the GFR measurement. Here we have ...

متن کامل

Dynamic Susceptibility Contrast Imaging using a multi-echo spiral sequence

Introduction To characterize microvasculature, one can perform a DCE-MRI experiment (a first injection of contrast agent (CA) to estimate the vessel wall permeability) followed by a DSC-MRI experiment (a second injection of CA to estimate relative blood volume (rCBV), relative blood flow, etc.) [1]. The DSC experiment can even yield information on vessel size if a gradient echo and a spin echo ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Magnetic Resonance Imaging

سال: 2003

ISSN: 1053-1807,1522-2586

DOI: 10.1002/jmri.10410