Measurement of Slice Thickness Using Partial Volume Effect in MR Imaging
نویسندگان
چکیده
منابع مشابه
Quantification of partial volume effects in planar imaging
Introduction: The limited resolution of the imaging system causes partial volume effects (PVEs). These results in spreading of image counts to the neighboring pixels. This phenomenon is called spill-out effect. This study aimed at quantifying PVEs using ImageJ. Methods:Technetium-99m solution of concentration of 74 kBq/ml was filled into spheres A, B<...
متن کاملPartial-volume effect in PET tumor imaging.
PET has the invaluable advantage of being intrinsically quantitative, enabling accurate measurements of tracer concentrations in vivo. In PET tumor imaging, indices characterizing tumor uptake, such as standardized uptake values, are becoming increasingly important, especially in the context of monitoring the response to therapy. However, when tracer uptake in small tumors is measured, large bi...
متن کاملOptimal slice thickness for object detection with longitudinal partial volume effects in computed tomography
Longitudinal partial volume effects (z-axial PVE), which occur when an object partly occupies a slice, degrade image resolution and contrast in computed tomography (CT). Z-axial PVE is unavoidable for subslice objects and reduces their contrast according to their fraction contained within the slice. This effect can be countered using a smaller slice thickness, but at the cost of an increased im...
متن کاملThe effect of slice order and thickness on fMRI activation data using multislice echo-planar imaging.
Multislice echo-planar imaging (EPI) is a commonly used technique for fMRI studies. Brain activation images acquired using fMRI are sensitive to T2* changes, reflecting the level of blood oxygenation (BOLD contrast), and may also contain an element of T1 contrast which detects blood flow changes in large vessels. If slice inflow (T1) effects are significant in multislice EPI, then as the order ...
متن کاملMeasurement of human brown adipose tissue volume and activity using anatomic MR imaging and functional MR imaging.
UNLABELLED The aim of this study was to assess the volume and function of human brown adipose tissue (BAT) in vivo using MR imaging. METHODS BAT volumes under thermoneutral conditions in the cervical areas were assessed via water-fat contrast using the Dixon method and via water-saturation efficiency using fast spin-echo and T2-weighted images. The existence of cervical BAT was also assessed ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 1998
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00001352024