Measuring Heat
نویسندگان
چکیده
منابع مشابه
A Hybrid Method for Measuring Heat Flux
This paper reports on the development and evaluation of a novel hybrid method for obtaining heat flux measurements. By combining spatial and temporal temperature measurements, it is shown that both the time response and accuracy of a heat flux sensor can be improved. This hybrid method was shown to increase the time response of a heat flux sensor mounted on a high conductivity material by a fac...
متن کاملCone Calorimeter – a Tool for Measuring Heat Release Rate
The cone calorimeter is considered the most significant bench scale instrument in fire testing. This apparatus has been adopted by the International Organization for Standardization (ISO 5660-1) for measuring heat release rate (HRR) of a sample. It has been shown that most fuels generate approximately 13.1 MJ of energy per kg of oxygen consumed. Therefore, HRR is based on the fact that the oxyg...
متن کاملRelaxation calorimetry technique for measuring low temperature specific heat
A rudimentary calorimeter was constructed to measure the temperature dependence of the specific heat of a 10 m thick ~0.62 mg! copolymer film of vinylidene fluoride and trifluoroethylene in the previously unexplored vicinity of 6 K. The data were processed with the algorithm developed by Hwang et al. @Rev. Sci. Instrum. 68, 94 ~1997!# as modified for our configuration in which a Cernox thermome...
متن کاملMeasuring the Heat Capacity of Superfluid He in the Presence of a Heat Flux Near T : Progress and Prospects
It has been predicted that the heat capacity of superfluid He will diverge strongly at a depressed transition temperature in the presence of a constant heat flux, Q. We have built a cell to measure this effect, and have taken preliminary measurements at various heat flux values. Our data indicate an enhancement of the heat capacity that varies as a function of Q. However, the temperature depend...
متن کاملPractical approach for measuring heat capacity of pharmaceutical crystals/glasses by modulated-temperature differential scanning calorimetry.
A practical protocol to obtain accurate heat capacity values of pharmaceutical compounds using modulated-temperature differential scanning calorimetry was established. Three pharmaceutical compounds, acetaminophen, indomethacin, and tri-O-methyl-β-cyclodextrin were used as model compounds. Powder samples did not produce reproducible results, presumably due to inclusion of gas in gap of powders ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nature
سال: 1884
ISSN: 0028-0836,1476-4687