Measuring the longitudinal relaxation time of GABA in vivo at 3 tesla
نویسندگان
چکیده
منابع مشابه
Rapid Parametric Mapping of the Longitudinal Relaxation Time T1 Using Two-Dimensional Variable Flip Angle Magnetic Resonance Imaging at 1.5 Tesla, 3 Tesla, and 7 Tesla
INTRODUCTION Visual but subjective reading of longitudinal relaxation time (T1) weighted magnetic resonance images is commonly used for the detection of brain pathologies. For this non-quantitative measure, diagnostic quality depends on hardware configuration, imaging parameters, radio frequency transmission field (B1+) uniformity, as well as observer experience. Parametric quantification of th...
متن کاملShort time T2 variability of the lumbar intervertebral disc – in vivo MRI study at 3 Tesla
D. Stelzeneder, S. Goed, G. H. Welsch, C. Hirschfeld, T. Paternostro-Sluga, K. Pieber, K. Friedrich, M. Reisegger, T. C. Mamisch, and S. Trattnig Department of Radiology, MR Centre, Medical University of Vienna, Vienna, Vienna, Austria, Department of Trauma Surgery, University of Erlangen, Erlangen, Germany, Department of Physical Medicine and Rehabilitation, Medical University of Vienna, Vienn...
متن کاملComparison of longitudinal metabolite relaxation times in different regions of the human brain at 1.5 and 3 Tesla.
In vivo longitudinal relaxation times of N-acetyl compounds (NA), choline-containing substances (Cho), creatine (Cr), myo-inositol (mI), and tissue water were measured at 1.5 and 3 T using a point-resolved spectroscopy (PRESS) sequence with short echo time (TE). T(1) values were determined in six different brain regions: the occipital gray matter (GM), occipital white matter (WM), motor cortex,...
متن کاملReal-Time Imaging at 3 Tesla
Introduction Modern real-time MRI (RT-MRI) involves the continuous acquisition, reconstruction, and display of images with 1) minimal acquisition time per image (usually < 100 ms) and 2) minimal acquisition-to-display latency (usually < 300 ms). It allows one to capture dynamic processes as they happen without the need for gating, breath-holding, or patient cooperation [1, 2], and has been made...
متن کاملReal-time cardiac MRI at 3 tesla.
Real-time cardiac and coronary MRI at 1.5T is relatively "signal starved" and the 3T platform is attractive for its immediate factor of two increase in magnetization. Cardiac imaging at 3T, however, is both subtly and significantly different from imaging at 1.5T because of increased susceptibility artifacts, differences in tissue relaxation, and RF homogeneity issues. New RF excitation and puls...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Magnetic Resonance Imaging
سال: 2012
ISSN: 1053-1807
DOI: 10.1002/jmri.23817