Mechanical Considerations in CW Linacs

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new geometric and mechanical verification device for medical LINACs

The goal of quality assurance (QA) for a radiation oncology medical LINAC is to maintain an acceptable level of equipment performance and reliability. The increasing complexity of Radiation Oncology equipment and treatment techniques have led to increased demands on the work load of the medical physicist. Regular testing needs to be as efficient as possible. Generally, the QA tests, as recommen...

متن کامل

emittance control in high power linacs

چکیده این پایان نامه به بررسی اثر سیم پیچ مغناطیسی و کاوه یِ خوشه گر با بسامد رادیویی بر هاله و بیرونگراییِ باریکه هایِ پیوسته و خوشه ایِ ذرات باردار در شتابدهنده های خطیِ یونی، پروتونی با جریان بالا می پردازد و راه حل هایی برای بهینه نگهداشتن این کمیتها ارایه می دهد. بیرونگرایی یکی از کمیتهای اساسی باریکه هایِ ذرات باردار در شتابدهنده ها است که تاثیر قابل توجهی بر قیمت، هزینه و کاراییِ هر شتابدهند...

Progress in Induction Linacs

This presentation will be a broad survey of progress in induction technology over the past four years. Much work has been done on accelerators for hydrodynamic test radiography and other applications. Solid-state pulsers have been developed which can provide unprecedented flexibility and precision in pulse format and accelerating voltage for both ion and electron induction machines. Induction l...

متن کامل

Induction Linacs

Abstract Induction linacs represent a somewhat unusual way of accelerating to medium energies particle beams of extremely high intensities. They generally operate in long-pulse mode where applications require high power beams. In this chapter we shall present the principle and main features of induction linacs and give information on the related problems of beam transport and the means to diagn...

متن کامل

Mechanical considerations in impaction bone grafting.

In impaction grafting of contained bone defects after revision joint arthroplasty the graft behaves as a friable aggregate and its resistance to complex forces depends on grading, normal load and compaction. Bone mills in current use produce a distribution of particle sizes more uniform than is desirable for maximising resistance to shear stresses. We have performed experiments in vitro using m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Nuclear Science

سال: 1985

ISSN: 0018-9499

DOI: 10.1109/tns.1985.4334164