Mechano-responsive microcapsules with uniform thin shells

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechano-activatable Microcapsules for Tunable Drug Delivery

Introduction A particularly desirable feature of controlled drug delivery is self-regulation, wherein physiological feedback actively regulates release kinetics. Extant systems in this domain commonly employ stimuli-responsive vehicles that rely on internal triggers to precipitate release, such as temperature, pH, or chemical reactions. 2 The sensitivity of these triggers can be tuned by biomat...

متن کامل

Robust and responsive silk ionomer microcapsules.

We demonstrate the assembly of extremely robust and pH-responsive thin shell LbL microcapsules from silk fibroin counterparts modified with poly(lysine) and poly(glutamic) acid, which are based on biocompatible silk ionomer materials in contrast with usually exploited synthetic polyelectrolytes. The microcapsules are extremely stable in an unusually wide pH range from 1.5 to 12.0 and show a rem...

متن کامل

Controlling release from pH-responsive microcapsules.

We report a microfluidic approach to produce monodisperse pH-responsive microcapsules with precisely controlled release behavior. The solid microcapsule shells are composed of a biocompatible pH-responsive polymer and robustly encapsulate an active material; however, when exposed to a trigger pH, the shells degrade and ultimately release the microcapsule contents. We control the trigger pH by u...

متن کامل

Formation of Uniform Polyaniline Thin Shells and Hollow Capsules Using Polyelectrolyte-Coated Microspheres as Templates

Multilayers of poly(diallyldimethylammonium chloride) and poly(sodium 4-styrenesulfonate) precoated onto melamine formaldehyde (MF) particles via the layer-by-layer (LbL) self-assembly procedure were used as templates for the subsequent deposition of polyaniline (PANI). Transmission electron microscopic (TEM) and scanning electron microscopic (SEM) images reveal that the as-prepared PANIcontain...

متن کامل

Functional attributes discriminating mechano-insensitive and mechano-responsive C nociceptors in human skin.

Microneurography was used in healthy human subjects to record action potentials from unmyelinated nerve fibers (C units) in cutaneous fascicles of the peroneal nerve. Activity-dependent slowing (n = 96) and transcutaneous electrical thresholds (n = 67) were determined. Eight units were sympathetic efferents according to their responses to sympathetic reflex provocations. Mechano-heat-responsive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Soft Matter

سال: 2019

ISSN: 1744-683X,1744-6848

DOI: 10.1039/c8sm02047g