Merging Zones Standard Addition Technique for Determination of Copper in Beer by Flow Injection Atomic Absorption Spectrophotometry
نویسندگان
چکیده
منابع مشابه
Gas-sampling technique for arsenic determination by atomic absorption spectrophotometry.
IN CONVENTIONAL atomic absorption spectrophotometry a solution of the sample is introduced into the flame as an aerosol by means of a nebulizer. However, commercial nebulizers are only about 5 efficient in forming fine droplets suitable for atomization by the flame ( I ) . Furthermore, a solution aspirated at a usual rate of 3-5 ml/min for about 10 sec produces a concentration signal extending ...
متن کاملDetermination of mercury by atomic-absorption spectrophotometry.
A flameless atomic-absorption system has been developed for the determination of low concentrations of mercury in gaseous, solid and liquid samples of organic and inorganic materials.
متن کاملDetermination of oxalic acid in urine by atomic absorption spectrophotometry.
A method is described for determination of oxalic acid in urine using atomic absorption spectrophotometry. The concentration of urinary oxalic acid is calculated by using the difference between two determinations of calcium: first, the excess of calcium in the supernatant after precipitation as calcium oxalate at pH 5, and second, the total calcium determined at pH less than 1 (endogenous and a...
متن کاملDetermination of mercury in fish by cold vapor atomic absorption spectrophotometry using a multicommuted flow injection analysis system.
A flow system was developed for the determination of total mercury concentration in fish samples by cold vapor atomic absorption spectrophotometry (CVAAS), based on the multicommuted flow injection analysis (MCFIA) approach. The system uses independently controlled solenoid valves for the introduction of reagents and samples. When not injected, solutions were recirculating to the reservoir bott...
متن کاملA continuous-dilution calibration technique for flame atomic-absorption spectrophotometry.
Calibration in atomic-absorption spectrometry is achieved by means of a concentrationgradient chamber using a single concentrated standard solution. Calibration is rapid and extends over the entire working concentration range of the analyte, irrespective of the shape of the conventionally obtained calibration curve. No curve-fitting approximations are involved. With well-designed apparatus, dev...