Metal Artifacts in Attenuation and Phase Contrast X-Ray Microcomputed Tomography: A Comparative Study
نویسندگان
چکیده
Abstract Background Metal artifacts arising around high-density components are a widely known problem in X-ray computed tomography (XCT) for both medical and industrial applications. Although phase contrast imaging XCT (PCI-XCT) is to be less prone metal caused by beam hardening, so far only little effort was made its comparison other, more established methods. Objective In the course of this work, absence literature addressed quantitative PCI-XCT attenuation (AC-XCT). Methods A polymer specimen including four Ti6Al4V inserts investigated PCI- AC-XCT with different pre-filter settings artifact reduction (MAR) algorithm. Artifacts image quality were evaluated streak index which provides metric assessment contrast-to-noise ratio (CNR). Results showed that significantly reduced matched combination hardware pre-filtering post-processing MAR However, leads worse CNR close surface could not removed sufficiently Conclusions This work demonstrates potential presents first
منابع مشابه
Imaging of poly(α-hydroxy-ester) scaffolds with X-ray phase-contrast microcomputed tomography.
Porous scaffolds based on poly(α-hydroxy-esters) are under investigation in many tissue engineering applications. A biological response to these materials is driven, in part, by their three-dimensional (3D) structure. The ability to evaluate quantitatively the material structure in tissue-engineering applications is important for the continued development of these polymer-based approaches. X-ra...
متن کاملHelical X-ray phase-contrast computed tomography without phase stepping
X-ray phase-contrast computed tomography (PCCT) using grating interferometry provides enhanced soft-tissue contrast. The possibility to use standard polychromatic laboratory sources enables an implementation into a clinical setting. Thus, PCCT has gained significant attention in recent years. However, phase-contrast CT scans still require significantly increased measurement times in comparison ...
متن کاملArtifacts in X-ray Dark-Field Tomography
Grating-based x-ray imaging provides three principle kinds of contrast: absorption, phase, and dark-field. Due to the availability of tomographic reconstruction algorithms for the dark-field contrast, it is now possible to take advantage of quantitative scatter information. However, the published algorithm is based on several assumptions that might be violated in reality. We use numerical simul...
متن کاملRecent advances in edge illumination x-ray phase-contrast tomography.
Edge illumination (EI) is an x-ray phase-contrast imaging technique, exploiting sensitivity to x-ray refraction to visualize features, which are often not detected by conventional absorption-based radiography. The method does not require a high degree of spatial coherence and is achromatic and, therefore, can be implemented with both synchrotron radiation and commercial x-ray tubes. Using diffe...
متن کاملAn iterative method to estimate x-ray attenuation coefficients in computed tomography
Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (D...