Method to Reduce Errors Due to Posture Changes in Lung Volume Estimation based on Torso-girth Measurement

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemoglobin-Dilution Method: Effect of Measurement Errors on Vascular Volume Estimation

The hemoglobin-dilution method (HDM) has been used to estimate changes in vascular volumes in patients because direct measurements with radioisotopes are time-consuming and not practical in many facilities. The HDM requires an assumption of initial blood volume, repeated measurements of plasma hemoglobin concentration, and the calculation of the ratio of hemoglobin measurements. The statistics ...

متن کامل

Metallic Foreign Body in the Lung Due to Gunshot Injury

A 37 - year- old man came to the hospital with a history of penetrating thoracoabdominal trauma due to gunshot wound in 10 days before. He underwent laparatomy and hepatorrhaphy in that time and right sided chest tube was inserted. Chest CT scan revealed metallic foreign body in lung tissue due to bullet burst. Right thoracotomy was performed and metallic foreign body extracted from lung tissue

متن کامل

Techniques to Reduce Measurement Errors in Challenging Environments

Test engineers face a unique set of challenges when measuring temperature, strain, pressure and flow in or near a test article in electrically noisy or hazardous environments. To address these issues, they often employ a centralized approach that involves placing data acquisition instrumentation in a control room located some distance from the test article. Transducers are then connected to the...

متن کامل

Change Estimates by Map Comparison: A Method to Reduce Erroneous Changes Due to Positional Error

A common method to assess land use/cover change (LUCC) is the comparison of digital maps of an area within a geographic information system (GIS). However, positional errors of the maps involved in the comparison affect this assessment and much of the change shown by means of this comparison may be an artifact due to these errors. This note presents a simple method to improve change estimates by...

متن کامل

Physicochemical changes in olive oil (cv. Koroneiki) due to fruit ripening and extraction method.

This study was conducted to find the effects of fruit ripening and extraction method on the quantity and quality of the Koroneiki olive oil. The oil samples extracted in six ripening stages were used for further quality analysis. Quality assessment of the oil was conducted according to the standard methods and the composition of fatty acids was measured by gas chromatography. The results showed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Biomechanisms

سال: 2014

ISSN: 1348-7116,1349-497X

DOI: 10.3951/biomechanisms.22.203