MIC Quality Control Guidelines and Disk Diffusion Test Optimization for CEM-101, a Novel Fluoroketolide

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MIC quality control guidelines and disk diffusion test optimization for CEM-101, a novel fluoroketolide.

The development of diagnostic susceptibility tests for CEM-101, a new fluoroketolide, was addressed by structured studies to determine the optimal disk diffusion test concentration and effects of various testing conditions or supplements and to establish the quality control (QC) ranges for reference broth microdilution tests. The 15-microg CEM-101 disk was selected, and MIC ranges for a total o...

متن کامل

Determination of Disk Diffusion and MIC Quality Control Guidelines for Solithromycin, a Novel Fluoroketolide Antibacterial, against Neisseria gonorrhoeae.

This solithromycin quality control study was performed to establish quality control (QC) ranges for the N. gonorrhoeae ATCC 49226 control strain for MIC agar dilution testing (AD) and zones by disk diffusion testing (DD). The following ranges were established: AD, 0.03 to 0.25 μg/ml, and DD, 33 to 43 mm. In January 2015, the CLSI Subcommittee on Antimicrobial Susceptibility Testing approved the...

متن کامل

Determination of disk diffusion and MIC quality control guidelines for JNJ-Q2, a novel quinolone.

JNJ-Q2 is a novel fluorinated 4-quinolone in development for treatment of acute bacterial skin and skin structure infection and community-acquired bacterial pneumonia. This quality control (QC) study was performed to establish ranges for control strains: Staphylococcus aureus ATCC 29213 (0.004 to 0.015 μg/ml), Enterococcus faecalis ATCC 29212 (0.015 to 0.06 μg/ml), Pseudomonas aeruginosa ATCC 2...

متن کامل

Determination of disk diffusion and MIC quality control guidelines for GSK2140944, a novel bacterial type II topoisomerase inhibitor antimicrobial agent.

GSK2140944 is a novel bacterial type II topoisomerase inhibitor in development for the treatment of conventional and biothreat pathogens, including Gram-positive pathogens and methicillin-resistant Staphylococcus aureus. This quality control study was performed to establish ranges for selected control strains: S. aureus ATCC 29213 and ATCC 25923, Escherichia coli ATCC 25922, Haemophilus influen...

متن کامل

Disk diffusion and MIC quality control ranges for BC-3205 and BC-3781, two novel pleuromutilin antibiotics.

MIC and disk diffusion quality control (QC) ranges were established for two new pleuromutilin antimicrobials (BC-3205 and BC-3781) in an eight-laboratory study performed according to Clinical and Laboratory Standards Institute M23-A3 guidelines. Staphylococcus aureus ATCC 29213 and 25923, Streptococcus pneumoniae ATCC 49619, and Haemophilus influenzae ATCC 4927 strains were evaluated. The propo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical Microbiology

سال: 2010

ISSN: 0095-1137,1098-660X

DOI: 10.1128/jcm.01992-09