Micro discharges in HVDC gas insulated systems

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of Ion Sources for Spacer Charging in SF6 Gas Insulated HVDC Systems

Stationary DC electric fields are determined by the resistivity distribution of the insulation materials. In the presence of interfaces between different insulation materials, charge accumulation at these boundary layers may have a significant influence on the electric field distribution and with it on the breakdown strength of the arrangement. In many previous works, surface charging of model ...

متن کامل

Fiber Optic Sensor for Acoustic Detection of Partial Discharges in Oil-Paper Insulated Electrical Systems

A fiber optic interferometric sensor with an intrinsic transducer along a length of the fiber is presented for ultrasound measurements of the acoustic emission from partial discharges inside oil-filled power apparatus. The sensor is designed for high sensitivity measurements in a harsh electromagnetic field environment, with wide temperature changes and immersion in oil. It allows enough sensit...

متن کامل

Detection in Spacer of Gas-Insulated Switchgears

With the increasing demand for precise condition monitoring and diagnosis of 11 gas-insulated switchgears (GIS), it has become a challenge to improve the detection sensitivity of 12 partial discharge (PD) induced in the GIS spacer. This paper deals with the elimination of the 13 capacitive component from the phase resolved partial discharge (PRPD) signal generated in GIS 14 spacer based on the ...

متن کامل

Introduction to gas discharges

This is a tutorial article. An introductory discussion of direct current gas discharges is presented. Beginning with basic ideas from kinetic theory, gas discharge plasmas are described in terms of phenomena observed in the laboratory. Various models are introduced to account for electrical breakdown, plasma boundaries and the longitudinal and transverse structure of discharges.

متن کامل

New 550-kV Gas-insulated Switchgear

OVERVIEW: Hitachi has developed smaller and more reliable gas-insulated switchgear (GIS) in response to demands for lower costs and stable power supplies. Reliability of this GIS was improved and the enclosure diameter was reduced in order to minimize the installation space by using new analysis techniques and rationalization in insulation design and in temperature rise criteria. Furthermore, t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Dielectrics and Electrical Insulation

سال: 2015

ISSN: 1070-9878

DOI: 10.1109/tdei.2015.004835