Microcomputer-assisted selection of optimum timing for titrant addition in automated potentiometric precipitation titration.
نویسندگان
چکیده
منابع مشابه
the test for adverse selection in life insurance market: the case of mellat insurance company
انتخاب نامساعد یکی از مشکلات اساسی در صنعت بیمه است. که ابتدا در سال 1960، توسط روتشیلد واستیگلیتز مورد بحث ومطالعه قرار گرفت ازآن موقع تاکنون بسیاری از پژوهشگران مدل های مختلفی را برای تجزیه و تحلیل تقاضا برای صنعت بیمه عمر که تماما ناشی از عدم قطعیت در این صنعت میباشد انجام داده اند .وهدف از آن پیدا کردن شرایطی است که تحت آن شرایط انتخاب یا کنار گذاشتن یک بیمه گزار به نفع و یا زیان شرکت بیمه ...
15 صفحه اولInvestigating the early stages of mineral precipitation by potentiometric titration and analytical ultracentrifugation.
Despite the importance of crystallization for various areas of research, our understanding of the early stages of the mineral precipitation from solution and of the actual mechanism of nucleation is still rather limited. Indeed, detailed insights into the processes underlying nucleation may enable a systematic development of novel strategies for controlling mineralization, which is highly relev...
متن کاملPotentiometric titration and conformational change in pepsinogen.
Potentiometric titrations of pepsinogen as functions of ionic strength and temperature were studied. It was found that the ionic strength has a minor effect on the titration behavior of the protein. The maximum values of the buffering capacity in the pH range of 6.0 to 9.0 were found at pH values corresponding to those at which a conformational change of the protein occurs as determined by opti...
متن کاملARM - Based Automatic Potentiometric Titration System
Accurate measurement and analysis are very important tasks for many applications ranging from industrial operations, analytical laboratories to biological processes. In modern analytical chemistry, automatic titrators have more prominence than manual interpretations. Various instruments have been developed and proposed in the past to carry out potentiometric titrations. Also there are suppliers...
متن کاملA Convenient Method for Potentiometric Titration of Chloride Ions
A convenient reference cell and method of potentiometric determination of chloride ions with silver nitrate is described. The method is accurate to about +/- 0.02 ml. 10(-4)M silver nitrate.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 1989
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.5.323