Microcrystal X-ray analyses using LTV camera at SPring-8 BL02B1 beamline
نویسندگان
چکیده
منابع مشابه
New soft X-ray beamline BL07LSU at SPring-8
A new soft X-ray beamline, BL07LSU, has been constructed at SPring-8 to perform advanced soft X-ray spectroscopy for materials science. The beamline is designed to achieve high energy resolution (E/ΔE> 10000) and high photon flux [>10(12) photons s(-1) (0.01% bandwidth)(-1)] in the photon energy range 250-2000 eV with controllable polarization. To realise this state-of-the-art performance, a no...
متن کاملSPring-8 beamline control system.
The SPring-8 beamline control system is now taking part in the control of the insertion device (ID), front end, beam transportation channel and all interlock systems of the beamline: it will supply a highly standardized environment of apparatus control for collaborative researchers. In particular, ID operation is very important in a third-generation synchrotron light source facility. It is also...
متن کامل[SPring-8 structural biology beamline].
Nowadays, three-dimensional structure of protein becomes important to understanding and application of molecular mechanisms in enzyme reaction, signal transduction and other various biochemical processes. The amount of the information is now growing quantitatively and qualitatively, supported in part by the technical development of macromolecular crystallography. In the development, brilliant s...
متن کاملRecent Progress in X-ray Emittance Diagnostics at Spring-8
At the SPring-8 storage ring, we have recently developed two X-ray instruments for emittance diagnostics. The one for a bending magnet source is the X-ray pinhole camera which directly images the beam profile. A pinhole in the atmosphere is composed of combined narrow X-Y slits made of tungsten. A scintillator crystal is used to convert the X-ray beam image to a visible image. The spatial resol...
متن کاملA hard X-ray nanospectroscopy station at SPring-8 BL39XU
We upgraded the hard X-ray spectroscopy beamline BL39XU at SPring-8 by installing Kirkpatrick-Baez mirrors to equip it with submicron-focusing capability. At the new experimental end-station located 74 m from the undulator source, an X-ray nanoprobe with a size of 120 × 100 nm has become available at 5–16 keV. This upgrade is fully compatible with the X-ray polarization tunability and helicity-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Crystallographica Section A Foundations of Crystallography
سال: 2005
ISSN: 0108-7673
DOI: 10.1107/s0108767305094237