Microelectrode Array Recordings from the Ventral Roots in Chronically Implanted Cats

The ventral spinal roots contain the axons of spinal motoneurons and provide the only location in the peripheral nervous system where recorded neural activity can be assured to be motor rather than sensory. This study demonstrates recordings of single unit activity from these ventral root axons using floating microelectrode arrays (FMAs). Ventral root recordings were characterized by examining ...

متن کامل

Revealing neuronal function through microelectrode array recordings

Microelectrode arrays and microprobes have been widely utilized to measure neuronal activity, both in vitro and in vivo. The key advantage is the capability to record and stimulate neurons at multiple sites simultaneously. However, unlike the single-cell or single-channel resolution of intracellular recording, microelectrodes detect signals from all possible sources around every sensor. Here, w...

متن کامل

In vitro microelectrode array technology and neural recordings.

In vitro microelectrode array (MEA) technology has evolved into a widely used and effective methodology to study cultured neural networks. An MEA forms a unique electrical interface with the cultured neurons in that neurons are directly grown on top of the electrode (neuron-on-electrode configuration). Theoretical models and experimental results suggest that physical configuration and biologica...

متن کامل

Seven Years of Recording from Monkey Cortex with a Chronically Implanted Multiple Microelectrode

A brush of 64 microwires was chronically implanted in the ventral premotor cortex of a macaque monkey. Contrary to common approaches, the wires were inserted from the white matter side. This approach, by avoiding mechanical pressure on the dura and pia mater during penetration, disturbed only minimally the cortical recording site. With this approach isolated potentials and multiunit activity we...

متن کامل

Multi-well microelectrode array recordings detect neuroactivity of ToxCast compounds.

Spontaneous activity in neuronal cultures on microelectrode arrays (MEAs) is sensitive to effects of drugs, chemicals, and particles. Multi-well MEA (mwMEA) systems have increased throughput of MEAs, enabling their use for chemical screening. The present experiments examined a subset of EPA's ToxCast compounds for effects on spontaneous neuronal activity in primary cortical cultures using 48-we...