Micropulse trans-scleral cyclophotocoagulation: treatment outcomes of refractory glaucoma in Malaysia
نویسندگان
چکیده
منابع مشابه
Trans-scleral Diode Laser Cyclophotocoagulation in Children with Refractory Glaucoma. Long-term Outcomes
The aim of this study was to evaluate the efficacy of diode laser cyclophotocoagulation in paediatric patients with refractory glaucoma and to assess complications associated with this method. The study included 69 eyes in 53 children with uncontrolled refractory glaucoma who underwent diode laser cyclophotocoagulation (cyclodiode) treatment. The mean age of this group was 6.1 years (range, 0.9...
متن کاملLong-term outcome of trans-scleral diode laser cyclophotocoagulation in refractory glaucoma.
BACKGROUND Long-term outcome and complications of diode laser cyclophotocoagulation (DCPC) may be important, since eyes, once treated with DCPC, are less likely to be subjected to other types of interventions in the further follow-up. METHODS Retrospective review of 131 eyes of 127 patients treated from 2000 through 2004. Success was defined as intraocular pressure (IOP) at last visit 6-21 mm...
متن کاملMicropulse transscleral diode laser cyclophotocoagulation in the treatment of refractory glaucoma.
BACKGROUND Transscleral diode laser cyclophotocoagulation (TSCPC) is an established method of treatment for refractory glaucoma, but is associated with significant complications. This study evaluates the efficacy and safety of a new form of TSCPC using micropulse diode laser and trans-pars plana treatment with a novel contact probe. METHODS Prospective interventional case series of 40 eyes of...
متن کاملMicropulse P3 Glaucoma Device Revolutionizes Cyclophotocoagulation
The newly patented MicroPulse P3 (MP3) device (Iridex) provides the surgeon a very safe and efficacious solution to treating glaucoma utilizing Iridex’s proprietary MicroPulse technology. While sharing similarities to G-Probe (Iridex), the primary advantage is the MP3 provides a kinder, gentler approach with identical efficacy yet improved safety profile.1 I have had the opportunity to be invol...
متن کاملMicropulse versus continuous wave transscleral diode cyclophotocoagulation in refractory glaucoma: a randomized exploratory study.
BACKGROUND The aim of this study was to compare the efficacy and safety of micropulse and continuous wave diode transscleral cyclophotocoagulation in refractory glaucoma. DESIGN Randomized, comparative, exploratory study in a tertiary hospital setting. PARTICIPANTS Patients with refractory, end-stage glaucoma. METHODS Forty-eight patients were randomized to either treatment. The intraocul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Malaysian Journal of Ophthalmology
سال: 2020
ISSN: 2665-9565,2665-9557
DOI: 10.35119/myjo.v2i4.112