Migration of a broken kirschner wire to the popliteal fossa following tension band wiring of a patellar fracture
نویسندگان
چکیده
منابع مشابه
Progressive migration of broken Kirschner wire into the proximal tibia following tension-band wiring technique of a patellar fracture--case report.
Wire breakage and migration is a known complication of using a wire tension band construct to treat displaced patella fractures. We report a case of a broken K-wire that migrated from the patella completely into the proximal tibia without complication 9 years after the index surgery. This report highlights the fact that wire migration can occur long after fracture healing and be relativel...
متن کاملMigration of a Kirschner wire to the dorsolateral side of the foot following osteosynthesis of a patella fracture with tension band wiring: a case report
BACKGROUND Patella fractures represent 1 % of all musculoskeletal system fractures. Fixation of patellar fractures using open reduction and tension band wiring is a commonly used and successful surgical fixation method. CASE PRESENTATION A 28-year-old male patient from Turkey presented to our clinic with complaints of palpable foreign bodies under the skin on the dorsolateral side of his righ...
متن کاملIntra-articular Migration of Broken Patellar Tension Band Wire: A Rare Case
INTRODUCTION Comminuted fracture of patella is most commonly treated by tension band wiring with cerclage wiring. Broken cerclage wiring after such surgery is not uncommon but intra-articular migration of broken cerclage wire is rarely known and described complication. CASE REPORT A 51-year-old male patient of Indian origin which was treated, 15 months back for fracture patella with tension b...
متن کاملArthroscopic Removal of a Wire Fragment from the Posterior Septum of the Knee following Tension Band Wiring of a Patellar Fracture
Tension band wiring with cerclage wiring is most widely used for treating displaced patellar fractures. Although wire breakage is not uncommon, migration of a fragment of the broken wire is rare, especially migration into the knee joint. We describe here a rare case of migration of a wire fragment into the posterior septum of the knee joint after fixation of a displaced patellar fracture with t...
متن کاملPercutaneous tension band wiring for patellar fractures.
PURPOSE To evaluate outcome of percutaneous tension band wiring for transverse fractures of the patella. METHODS 16 men and 7 women aged 27 to 65 (mean, 40) years underwent percutaneous tension band wiring for transverse fractures of the patella with a displacement of >3 mm. Pain, operating time, mobility, functional score, and complications were evaluated. RESULTS 20 patients underwent suc...