Minimally invasive ablation of a toxic thyroid nodule by high-intensity focused ultrasound.
HIFU is used in the treatment of cancer (prostate, breast) and uterine fibroma but not yet in TNs. This case report describes the first successful ablation of a toxic TN with HIFU. TSH and radioiodine scan normalization were achieved without complications and maintained for 18 months. HIFU treatment is a minimally invasive technique that may be an effective safe alternative to radioiodine or su...
متن کاملThermography in High-Intensity Focused Ultrasound Ablation
Application of high-intensity focused ultrasound (HIFU) in therapeutic medicine has started in the 1950s for the treatment of Parkinson’s disease. With the development of medical diagnosis, such as ultrasound imaging and magnetic resonance imaging (MRI), automatic control, imaging processing and electrical technology, extracorporeal and intrarectal HIFU systems have been developed for clinical ...
متن کاملInterstitial devices for minimally invasive thermal ablation by high-intensity ultrasound.
Interstitial ultrasound applicators have been proposed for treating deep-seated tumours that cannot be reached with extra-corporeal high-intensity focused ultrasound. In addition, interstitial ultrasound offers several advantages compared with conventional ablation technology (radiofrequency, microwaves, cryotherapy) in terms of penetration, speed of coagulation, ability to direct and control t...
متن کاملHigh intensity focused ultrasound (HIFU) ablation of benign thyroid nodules – a systematic review
BACKGROUND With an increasing number of imaging studies being done nowadays, the number of incidentally discovered thyroid nodules is expected to rise. Although many of these nodules are small and benign in nature, some do grow and may cause pressure and/or thyrotoxic symptoms. Surgical resection has traditionally been recommended for symptomatic nodules but is associated with risk of hypothyro...
متن کاملThe efficacy and safety of high-intensity focused ultrasound ablation of benign thyroid nodules
High-intensity focused ultrasound (HIFU) is a promising form of thermal ablation of benign thyroid nodules, but evidence supporting its use is scarce. The present review evaluated the efficacy and safety of single-session HIFU treatment of benign thyroid nodules. As reported in the literature, the extent of nodule shrinkage following treatment ranged from 48.8% to 68.8%. Like other forms of abl...