Minimally Invasive Plate Osteosynthesis Using a Locking Compression Plate for Distal Femoral Fractures
نویسندگان
چکیده
منابع مشابه
Minimally invasive plate osteosynthesis using a locking compression plate for distal femoral fractures.
PURPOSE To evaluate treatment outcomes of minimally invasive plate osteosynthesis (MIPO) for distal femoral fractures in 31 patients. METHODS 22 male and 9 female consecutive patients aged 21 to 65 (mean, 42) years underwent minimally invasive plate osteosynthesis using a locking compression plate (LCP) for distal femoral fractures. The causes of injury were vehicular accidents (n=24), falls ...
متن کاملMinimally invasive plate osteosynthesis using a locking compression plate for diaphyseal humeral fractures.
PURPOSE To assess outcomes of minimally invasive plate osteosynthesis (MIPO) using a locking compression plate (LCP) for 42 humeral shaft fractures. METHODS. 28 men and 14 women aged 18 to 68 (mean, 34; median, 29) years underwent closed reduction and MIPO using a LCP for type 12-A (n=26) and type 12-B (n=16) humeral shaft fractures. Eight of the patients were aged ≥ 50 years. Patients were fol...
متن کاملMinimally Invasive Plate Osteosynthesis with Locking Compression Plate for Distal Diametaphyseal Tibia Fracture
Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology of distal t...
متن کاملMinimally invasive plate osteosynthesis with locking compression plate for distal diametaphyseal tibia fracture.
BACKGROUND Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology ...
متن کاملMinimally invasive plate osteosynthesis for distal radius fractures
BACKGROUND Fractures of distal radius are common injury in all age groups. Cast treatment with or without close reduction is a viable option. However, the results are often unsatisfactory with restricted function. The open reduction and internal fixation often results in extensive soft tissue dissection and associated high rates of infect and delayed/nonunion. The distractor/external fixator ha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Orthopaedic Surgery
سال: 2011
ISSN: 2309-4990,2309-4990
DOI: 10.1177/230949901101900211