Minimally Invasive Plate Osteosynthesis for Distal Tibia Fractures.
Surgical treatment of distal tibia fractures can present as a difficult task. Intramedullary nailing (IMN), external fixation, and open reduction internal fixation (ORIF) have displayed various complications ranging from a high rate of knee morbidity with IMN to wound complications and infection with ORIF. Minimally invasive plate osteosynthesis (MIPO) has been used to decrease development of t...
متن کاملDistal radius fractures: Minimally invasive plate osteosynthesis with dorsal bicolumnar locking plates fixation
BACKGROUND Controversy still exists regarding the current treatment modalities for unstable distal radius fractures. There are yet few articles investigating the efficacy of bicolumnar dorsal plating technique, which is designed to minimize tissue dissection while providing sufficiently secure fixation. A clinical study was performed to evaluate the feasibility of the minimally invasive plate o...
متن کاملMinimally Invasive Plate Osteosynthesis with Locking Compression Plate for Distal Diametaphyseal Tibia Fracture
Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology of distal t...
متن کاملMinimally invasive plate osteosynthesis with locking compression plate for distal diametaphyseal tibia fracture.
BACKGROUND Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology ...
متن کاملMinimally invasive plate osteosynthesis using a locking compression plate for distal femoral fractures.
PURPOSE To evaluate treatment outcomes of minimally invasive plate osteosynthesis (MIPO) for distal femoral fractures in 31 patients. METHODS 22 male and 9 female consecutive patients aged 21 to 65 (mean, 42) years underwent minimally invasive plate osteosynthesis using a locking compression plate (LCP) for distal femoral fractures. The causes of injury were vehicular accidents (n=24), falls ...