منابع مشابه
Minimax Current Density Coil Design
Introduction Gradient and shim coils are required to generate a magnetic field of particular spatial form when energised with electric current. The design of these coils is a well studied inverse problem [1] that is inherently ill-conditioned with an infinite number of solutions. In order to obtain a single solution, the system must be regularised, which is commonly achieved by minimising the s...
متن کاملDesign Modification of Rogowski Coil for Current Measurement in Low Frequency
The principle object of this paper is to offer a modified design of Rogowski coil based on its frequency response. The improvement of the integrator circuit for nullifying the phase difference between the waveforms of the measured-current and the corresponding terminal voltage is a further object of this investigation. This paper addresses an accurate, yet more efficient measuring and protect...
متن کامل3-D RF Coil Design Considerations for MRI
High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...
متن کاملStatic Coil Design Considerations for the Magnetic Resonance Imaging
One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...
متن کاملComplete Design Equation for Gradient Coil Design Using Loop-Current Elements
INTRODUCTION We have previously proposed a gradient coil design method using loop currents with some preliminary results [I]. The purpose of this paper is to complete the design equation of the gradient coil design using loop-current elements. The advantages of the proposed method are: (1) Ability for either the minimum-inductance or the minimum-power design or even for a combined, weighted min...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics D: Applied Physics
سال: 2010
ISSN: 0022-3727,1361-6463
DOI: 10.1088/0022-3727/43/9/095001