The increasing presence of wind power in power systems will likely drive the integration of large wind farms with electrical networks that are series-compensated to sustain large power flows. This may potentially lead to subsynchronous resonance (SSR) issues. In this paper, a supplementary controller on the grid-side converter (GSC) control loop is designed to mitigate SSR for wind power system...
متن کاملDFIG Based Wind Turbines Behavior Improvement during Wind Variations using Fractional Order Control Systems
This paper is concerned with behavior analysis and improvement of wind turbines with Doubly Fed Induction Generator (DFIG) when using a new fractional-order control strategy during wind variations. A doubly fed induction generator, two types of variable frequency power electronic converters and two input wind waveforms are considered. A fractional-order control strategy is proposed for the wind...
متن کاملGrowing Neural Gas Based MPPT for Wind Generator using DFIG
This paper presents Growing Neural Gas (GNG) based a maximum power point tracking (MPPT) technique for a high performance wind generator using DFIG. It is used in variable speed wind energy conversion system. Here, two back to back converters is used and connected to the stator, correspondingly FOC and VOC is done on machine and supply side converter. Constant voltage over the grid is obtained ...
متن کاملDamping analysis of sub-synchronous resonance (SSR) in a wind farm based on DFIG in a series compensated network
The effect of wind generator on sub-synchronous resonance (SSR) is being interested by increasing penetration of wind turbine in power systems,. Purpose of this article is to analyze SSR in a wind farm based on doubly fed induction generator (DFIG) which is connected to compensating series grid. A dynamic model for analysis of induction generator effect and Torsional Interaction (TI) has been u...
متن کاملCombined Use of Sensitivity Analysis and Hybrid Wavelet-PSO- ANFIS to Improve Dynamic Performance of DFIG-Based Wind Generation
In the past few decades, increasing growth of wind power plants causes different problems for the power quality in the grid. Normal and transient impacts of these units on the power grid clearly indicate the need to improve the quality of the electricity generated by them in the design of such systems. Improving the efficiency of the large-scale wind system is dependent on the control parameter...