Mitigation and analysis of sub synchronous resonance for DFIG based wind farm using STATCOM controller

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Damping analysis of sub-synchronous resonance (SSR) in a wind farm based on DFIG in a series compensated network

The effect of wind generator on sub-synchronous resonance (SSR) is being interested by increasing penetration of wind turbine in power systems,. Purpose of this article is to analyze SSR in a wind farm based on doubly fed induction generator (DFIG) which is connected to compensating series grid. A dynamic model for analysis of induction generator effect and Torsional Interaction (TI) has been u...

متن کامل

Dynamic Performance Analysis of DFIG based Wind Farm with STATCOM and SVC

To meet the strict criteria of grid codes for the integrated wind farm with the grid has become a major point of concern for engineers and researchers today. Moreover voltage stability is a key factor for the stable operation of grid connected wind farm during fault ride through and grid disturbances. This paper investigates the implementation and comparison of FACTS devices like STATCOM and SV...

متن کامل

Analysis and simulation of dynamic performance for DFIG-based wind farm connected to a distrubition system

Local renewable resources such as wind and solar are often available in remote locations. Wind farms consist of many individual wind turbines which are connected to the electric power transm­iss­i­o­n ne­tw­o­r­k­. A wind farm can use the wind resources from a certain area efficiently. Double-fed induction generator (DFIG) is a gene­rating principle widely used in wind turbine (WT). DFIG are ab...

متن کامل

Improving the performance of wind turbine equipped with DFIG using STATCOM based on input-output feedback linearization controller

Using the FACTS controllers, such as static synchronous compensator (STATCOM), as it provides continuous reactive power, in the grid including wind turbine (WT) equipped with doubly fed induction generator, for improving voltage profile (under normal circumstances) and providing a transition ability from inductor generator transition state has been proposed. In this paper, in order to contr...

متن کامل

Improving the performance of wind turbine equipped with DFIG using STATCOM based on input-output feedback linearization controller

Using the FACTS controllers, such as static synchronous compensator (STATCOM), as it provides continuous reactive power, in the grid including wind turbine (WT) equipped with doubly fed induction generator, for improving voltage profile (under normal circumstances) and providing a transition ability from inductor generator transition state has been proposed. In this paper, in order to contr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IOP Conference Series: Materials Science and Engineering

سال: 2021

ISSN: 1757-8981,1757-899X

DOI: 10.1088/1757-899x/1055/1/012140