Mitigation of operational losses in matrix converter fed DFIG for WECS

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mitigation of operational losses in matrix converter fed DFIG for WECS

With the change in the wind profile, the speed of doubly fed induction generator (DFIG) of wind energy conversion system (WECS) changes from super synchronous to sub synchronous range and vice versa. DFIG is operated to generate quality power; hence, power at rotor side is controlled using matrix converter taking power from grid and feeding back power to the grid depending on the wind profile. ...

متن کامل

Sensor Fault Tolerant Control For DFIG With WECS

Wind Energy Conversion Systems are the most striking renewable energy resources available to generate the electricity. Doubly-fed Induction Generator (DFIG) based wind turbine with variable speed is the most common wind turbine in the growing wind market. In any WECS, power flow must be maintained at all instant irrespective of any fault in the system. This paper deals with fault tolerant contr...

متن کامل

Energy Losses and Operational Costs of Radon Mitigation Systems

Energy losses and operational costs of radon mitigation systems in typical locations within the various heating zones in the USA have been calculated that include a modeling of seasonal and daily temperature variations. Two types of energy losses are compared with the electrical energy consumption for various ventilators that will be presented graphically. These energy losses will also be compa...

متن کامل

Dynamic Performance Of DFIG Based WECS Under Different Voltage Sag

At the present time Doubly Fed Induction Generator (DFIG) based wind energy conversion systems are widely used for large wind power plants. DFIG offers many advantages for instance reduced rating power converter, low cost and reduced losses with the better efficiency, easy in realization of power factor correction schemes, variable speed operation and four quadrants active and reactive power co...

متن کامل

Active and Reactive Power Management of Wind Farm Based on a Six Leg Tow Stage Matrix Converter Controlled by a Predictive Direct Power Controller

In this paper we propose a new configuration of the wind farm connecting with an electrical grid. The proposed Wind Energy Conversion System (WECS) is based on a two stages six-leg matrix converter using to drive a two Doubly Fed Induction Machines operating at different wind speeds. Each Doubly Fed Induction Generator (DFIG) is controlled through the rotor currents using the Finite Set Model P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Renewables: Wind, Water, and Solar

سال: 2015

ISSN: 2198-994X

DOI: 10.1186/s40807-015-0007-z