Mixed-conduction mechanism of Cr2Ge2Te6 film enabling positive temperature dependence of electrical conductivity and seebeck coefficient

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multifunctional probes for high-throughput measurement of Seebeck coefficient and electrical conductivity at room temperature.

An apparatus capable of rapid measurement of the Seebeck coefficient and electrical resistivity at room temperature is reported. The novel aspect of this apparatus is the use of 4 multifunctional probes that comprise a junction of two conductors at the tip and serve as both thermocouples and electrical contacts. In addition, one of the probes has a built-in heater that can establish a temperatu...

متن کامل

Simultaneous increase in electrical conductivity and Seebeck coefficient in highly boron-doped nanocrystalline Si.

A large thermoelectric power factor in heavily boron-doped p-type nanograined Si with grain sizes ∼30 nm and grain boundary regions of ∼2 nm is reported. The reported power factor is ∼5 times higher than in bulk Si. It originates from the surprising observation that for a specific range of carrier concentrations, the electrical conductivity and Seebeck coefficient increase simultaneously. The t...

متن کامل

Temperature dependence of the electrical conductivity of imidazolium ionic liquids.

The electrical conductivities of 1-alkyl-3-methylimidazolium tetrafluoroborate ionic liquids and of 1-hexyl-3-methylimidazolium ionic liquids with different anions were determined in the temperature range between 123 and 393 K on the basis of dielectric measurements in the frequency range from 1 to 10(7) Hz. Most of the ionic liquids form a glass and the conductivity values obey the Vogel-Fulch...

متن کامل

Apparatus for Seebeck coefficient and electrical resistivity measurements of bulk thermoelectric materials at high temperature

A high temperature Seebeck coefficient and electrical resistivity measurement apparatus has been designed and built for measuring advanced thermoelectric materials. The apparatus covers the range of temperatures from 300 to 1300 K. Different sources of errors involved in the two measurements are discussed. The accuracy of the electrical resistivity measurement is estimated to be better than ±1%...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Results in Materials

سال: 2020

ISSN: 2590-048X

DOI: 10.1016/j.rinma.2020.100155