Mode-resolved photon counting via cascaded quantum frequency conversion
نویسندگان
چکیده
منابع مشابه
Photon-Counting Arrays for Time-Resolved Imaging
The paper presents a camera comprising 512 × 128 pixels capable of single-photon detection and gating with a maximum frame rate of 156 kfps. The photon capture is performed through a gated single-photon avalanche diode that generates a digital pulse upon photon detection and through a digital one-bit counter. Gray levels are obtained through multiple counting and accumulation, while time-resolv...
متن کاملMultidimensional mode-separable frequency conversion for high-speed quantum communication
PARITOSH MANURKAR,* NITIN JAIN, MICHAEL SILVER, YU-PING HUANG, CARSTEN LANGROCK, MARTIN M. FEJER, PREM KUMAR, AND GREGORY S. KANTER Department of Electrical Engineering and Computer Science, Northwestern University, Evanston, Illinois 60208, USA Department of Physics and Engineering Physics, Stevens Institute of Technology, Hoboken, New Jersey 07030, USA E. L. Ginzton Laboratory, Stanford Unive...
متن کاملFrequency-Resolved Optical Gating Using Cascaded Second-Order Nonlinearities
We demonstrate frequency-resolved optical gating (FROG) using cascaded second-order nonlinearities (up-conversion followed by down-conversion). We describe two different cascaded second-order beam geometries—selfdiffraction and polarization-gate—which are identical to their third-order nonlinear-optical cousins, except that they use second-harmonic-generation crystals instead of (weaker) thirdo...
متن کاملTime-Resolved Two-Photon Quantum Interference
The interference of two independent single-photon pulses impinging on a beam splitter is analysed in a generalised time-resolved manner. Different aspects of the phenomenon are elaborated using different representations of the single-photon wave packets, like the decomposition into single-frequency field modes or spatio-temporal modes matching the photonic wave packets. Both representations lea...
متن کاملMultichannel photon counting instrument for spatially resolved near infrared spectroscopy
We have developed a multichannel photon counting instrument for near infrared spatially resolved spectroscopy. The instrument uses two laser diodes at 780 and 830 nm. The two wavelengths are time multiplexed at a rate of 5 MHz for virtually simultaneous measurements at the two wavelengths. The photon pulses are then multiplexed with an optical switch so that the incident optical signals are dir...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Letters
سال: 2013
ISSN: 0146-9592,1539-4794
DOI: 10.1364/ol.38.000468