Modelling of Bidirectional Three-Phase Four-Wire Three-Level NPC MLC under Single-Loop Current Sensorless Control
نویسندگان
چکیده
Single-loop current sensorless control allows for abolishing of the instantaneous measurement in system using only a single loop with voltage feedback to stabilise DC-bus voltage. This approach eliminates sensors circuit, benefiting from saving space on printed circuit board and minimising power dissipation circuitry. paper focuses single-loop applied bidirectional three-phase four-wire three-level NPC MLC by simulation analysis demonstrates performance proposed algorithm rectifier inverter modes step response direction change grid-voltage change. In capacitor balancing, an additional controller is applied, which capable compensating asymmetry caused adding 2.5 kOhm resistor parallel one capacitors. Our results demonstrate good method both modes, showing stable shape low full acceptable harmonics content, meeting requirements IEC 61000-3-2 standard Class A devices. The showed that suitable industrial application.
منابع مشابه
Adaptive Hysteresis Current Control of Shunt Active Filter for Three Phase Four-wire System
In a balanced three phase system, only harmonics of positive sequence(7 th , 13 th ,..etc) and negative sequence (5 th , 11 th ,…etc) are produced. However, the harmonic currents produced by single phase non-linear loads like switch-mode power supplies in computer which are connected between phase to neutral injects third order zero sequence harmonics (3 rd ,9 th ,15 th …etc) (Mehmet et al 2008...
متن کاملA Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks
The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...
متن کاملClosed Loop Control of Three-Phase PWM Rectifier through A Single DC Line Current Sensor
This paper presents a new current control method for three phase pulse width modulation rectifiers using single dc current sensor. Conventional three-phase PFC control requires sensing of at least two input phase currents. The proposed current control method solves the problems of conventional methods by controlling a three phase PWM rectifier using only the dc-rail current as the feedback sign...
متن کاملSingle-Shunt Three-Phase Current Reconstruction Algorithm for Sensorless FOC of a PMSM
Field-oriented control can be implemented using position sensors such as encoders, resolvers or Hall sensors. However, not all motor control applications require such granularity given by a resolver or encoder; and, in many cases, they do not require control at zero speed. These applications are a perfect target for using sensorless techniques in which the motor position can be estimated using ...
متن کاملThree-Phase, Four-Wire UPQC Topology with Reduced Switching Losses
The paper introduces the modified UPQC topology with reduced switching losses. UPQC is a versatile custom power device which consists of two inverters connected back to back and deals with both load current and supply voltage imperfections. It can simultaneously perform as shunt and series active power filters. The series part of the UPQC acts as Dynamic Voltage Restorer (DVR). It is used to ma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2023
ISSN: ['1996-1073']
DOI: https://doi.org/10.3390/en16124599