Modified Draping to Avoid Fluid Leakage in Cranial Surgery. Technical Note.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modified draping to avoid fluid leakage in cranial surgery--technical note.

Contamination under draping due to leakage of fluid from the surgical field should be avoided to maintain cleanness. A modified draping method was developed using standard draping materials but with an irrigation pouch applied directly to the scalp. The present method prevents fluid leakage along the scalp, increases surgeon comfort, and reduces postoperative room cleaning.

متن کامل

Endoscopic Endonasal Skull Base Surgery: Advantages, Limitations, and Our Techniques to Overcome Cerebrospinal Fluid Leakage: Technical Note

In recent years, resections of midline skull base tumors have been conducted using endoscopic endonasal skull base (EESB) approaches. Nevertheless, many surgeons reported that cerebrospinal fluid (CSF) leakage is still a major complication of these approaches. Here, we report the results of our 42 EESB surgeries and discuss the advantages and limits of this approach for resecting various types ...

متن کامل

Technical Note on Modified Posterior Approach to the Hip Joint

INTRODUCTION The posterior approach is the most commonly and relatively easy to be used to expose the hip joint. Posterior approaches allow excellent visualization of the entire acetabulum and the upper femoral shaft, and thus they are popular for revision joint replacement surgery particularly in cases where only the femoral component needs to be replaced. There may be a higher dislocation rat...

متن کامل

Modified Hemostatic Technique Using Microfibrillar Collagen Hemostat in Endoscopic Endonasal Transsphenoidal Surgery: Technical Note

Microfibrillar collagen hemostat (MCH) is accepted as an effective topical hemostatic agent during endoscopic endonasal transsphenoidal surgery (EETS), particularly to achieve venous hemostasis; however, handling MCH may be troublesome because of its adherence to gloves and instruments. We describe here a method of "injection" of MCH suspension using a syringe applicator. This technique allows ...

متن کامل

Technical review and considerations for a cerebrospinal fluid leakage study.

Within the past decade, published diagnostic algorithms for cerebrospinal fluid (CSF) leakage have included beta-2-transferrin analysis, rigid nasal endoscopy, high-resolution CT, CT cisternography, CT fluorescein lumbar puncture, and MRI but have not included the nuclear medicine CSF leakage study. However, some physicians still use this study today. This case report reviews the procedure and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Neurologia medico-chirurgica

سال: 2001

ISSN: 0470-8105,1349-8029

DOI: 10.2176/nmc.41.466