Modified long-axis in-plane ultrasound technique versus conventional palpation technique for radial arterial cannulation

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Success Rate of Radial Artery Cannulation under Ultrasound Guidance and Palpation Technique in Adults.

BACKGROUND Previous studies have shown ultrasound guidance (USG)for arterial cannulation being advantageous compared to palpation technique, but little is known about its performance by novices. OBJECTIVE This study was to compare the utility of USG radial artery cannulation with palpation technique in terms of success rate, real-time to placement, number of attempts and complications. MATE...

متن کامل

Comparative study of ultrasound guided subclavian venous cannulation versus conventional technique: Advantages and disadvantages

Paediatric cardiac surgical patients need safe intravenous access for hemodynamic monitoring, drug infusion, parenteral nutrition, post operative difficult peripheral venous access, blood withdrawal for lab investigations for post operative period, blood product transfusion. Internal Jugular vein insertion caused discomfort and pain to patients while femoral venous cannulation causes increased ...

متن کامل

Internal Jugular Vein Cannulation: An Ultrasound-Guided Technique Versus a Landmark-Guided Technique

OBJECTIVES To compare the landmark-guided technique versus the ultrasound-guided technique for internal jugular vein cannulation in spontaneously breathing patients. METHODS A total of 380 patients who required internal jugular vein cannulation were randomly assigned to receive internal jugular vein cannulation using either the landmark- or ultrasound-guided technique in Bursa, Uludag Univers...

متن کامل

Vitrification versus conventional cryopreservation technique

During in vitro fertilization treatment (IVF), a surplus of oocytes is produced which results in a surplus of embryos which must be preserved. Due to the recent tendency in ART treatment to transfer fewer embryos in order to avoid multiple pregnancies, partly a result of new laws and guidelines aimed at controlling the number of embryos to be transferred and the number of oocytes to be fertiliz...

متن کامل

A modified technique for umbilical arterial catheterization.

A modified technique for umbilical artery catheterization was assessed in babies in whom conventional method failed or if the cord was dry. Success rate attained with the modified technique was 90% (19/21). This modified technique could provide an easier and faster method for successful umbilical arterial catheterization.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Medicine

سال: 2020

ISSN: 0025-7974,1536-5964

DOI: 10.1097/md.0000000000018747