Harmonic Mitigation Using Inverter Based Hybrid Shunt Active Power Filter

With the rapid developments and use of non linear loads, the controlling over the harmonic current to get and maintain power quality is becoming more important. Active power filters has been used to compensate the harmonic pollution in our power system. This paper presents a efficient model to compensate the current harmonics using the inverter based Shunt Active Power Filter, Passive Power Fil...

متن کامل

On design and implementation of three phase three level shunt active power filter for harmonic reduction using synchronous reference frame theory

Shunt active power filter is commonly used to eliminate current harmonics generated in the source side due to presence of non-linear loads. This scheme consists of three phase three level diode clamped multilevel inverter and a DC capacitor that act as a shunt active power filter to mitigate the supply current harmonics and inject the required reactive power to non-linear loads. In this paper, ...

متن کامل

Neural-Networks and Synchronous Reference Frame Applied in the Harmonic Compensation with a Three-Phase Parallel Active Power Filter

This paper presents an alternative method based on artificial neural network, which is used to obtain the reference currents for harmonic current suppression and reactive power compensation in a shunt active power filter applied to three-phase four-wire system. The neural network consists of a multilayer perceptron, which is trained to estimate the peak amplitude of the load fundamental compone...

متن کامل

Investigation of Harmonic Detection Techniques for Shunt Active Power Filter

Active power filters are used to eliminate current harmonics of non-linear loads. This paper evaluates three different methods of determining the compensating current for a shunt active filter that is working under nonsymmetrical conditions. The paper compares the instantaneous reactive power theory, the synchronous reference frame theory and fast Fourier transform techniques. The comparison is...

متن کامل

Minimally Switched Shunt active Power Filter Inverter for Harmonic Mitigation

Active filters provide significant harmonic and reactive power compensation and are thereby widely accepted as devices for power quality enhancement.. Many research works have been done to improve the dynamic performance of active filters. Current research work focuses on implementing a Minimally Switched Shunt Active Power filter for power quality enhancement. Minimally switched grid interacti...