Modulation factors calculated with an EPID‐derived MLC fluence model to streamline IMRT/VMAT second checks
This work outlines the development of a robust method of calculating modulation factors used for the independent verification of MUs for IMRT and VMAT treatments, to replace onerous ion chamber measurements. Two-dimensional fluence maps were calculated for dynamic MLC fields that include MLC interleaf leakage, transmission, and tongue-and-groove effects, as characterized from EPID-acquired imag...
متن کاملThe impact of MLC transmitted radiation on EPID dosimetry for dynamic MLC beams.
The purpose of this study was to experimentally quantify the change in response of an amorphous silicon (a-Si) electronic portal imaging device (EPID) to dynamic multileaf collimator (dMLC) beams with varying MLC-transmitted dose components and incorporate the response into a commercial treatment planning system (TPS) EPID prediction model. A combination of uniform intensity dMLC beams and stat...
متن کاملAn EPID‐based system for gantry‐resolved MLC quality assurance for VMAT
Multileaf collimator (MLC) positions should be precisely and independently mea-sured as a function of gantry angle as part of a comprehensive quality assurance (QA) program for volumetric-modulated arc therapy (VMAT). It is also ideal that such a QA program has the ability to relate MLC positional accuracy to patient-specific dosimetry in order to determine the clinical significance of any dete...
متن کاملAnatomy‐based, patient‐specific VMAT QA using EPID or MLC log files
In this project, we investigated the use of an electronic portal imaging device (EPID), together with the treatment planning system (TPS) and MLC log files, to determine the delivered doses to the patient and evaluate the agreement between the treatment plan and the delivered dose distribution. The QA analysis results are presented for 15 VMAT patients using the EPID measurements, the ScandiDos...
متن کاملAn EPID-based method for comprehensive verification of gantry, EPID and the MLC carriage positional accuracy in Varian linacs during arc treatments
BACKGROUND In modern radiotherapy, it is crucial to monitor the performance of all linac components including gantry, collimation system and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method has been introduced in conjunction with an algorithm to investigate the stability of these systems during arc treatments with the aim of en...