Moment – rotation dependence under fire conditions for steel beam-to-column joint with known flexibility
نویسندگان
چکیده
منابع مشابه
Retrofitting of Beam-Column Joint Using CFRP and Steel Plate
─This paper presents the retrofitting of beam-column joint using CFRP (Carbon Fiber Reinforced Polymer) and steel plate. This specimen was tested until failure up to 1.0% drift. This joint suffered severe damages and diagonal cracks at upper crack at upper column before retrofitted. CFRP were wrapped at corbel, bottom and top of the column. Steel plates with bonding were attached to the two bea...
متن کاملDamage Avoidance Design Steel Beam-Column Moment Connection Using High-Force-To-Volume Dissipators
Existing welded steel moment frames are designed to tolerate substantial yielding and plastic rotation under earthquake loads. This sacrificial design approach can lead to permanent, and often irreparable damage when interstory drifts exceed 2%. The experimental seismic performance of a 50% full-scale damage avoidance designed structural steel beam-column connection is presented. The beamcolumn...
متن کاملInfluence of Sudden Column Loss on Dynamic Response of Steel Moment Frames under Blast Loading
Modeling buildings response to blast and subsequent progressive collapse interested more and more researchers during the past two decades. Due to the threat from extreme loading, efforts have been made to develop methods of structural analysis and design. In this paper, progressive collapse capacity of steel moment frames was first investigated using alternate load path method, then a nonlinear...
متن کاملNonlinear Numerical Analyses of a Fabricated Connection of Concrete-Filled Steel Column to Steel Beam Under Low-Reversed Cyclic Loading
RESEARCH ARTICLE Nonlinear Numerical Analyses of a Fabricated Connection of Concrete-Filled Steel Column to Steel Beam Under Low-Reversed Cyclic Loading Chunyi Cui, Kun Meng, Yan Kong, Yannian Zhang and Wenxin Zuo Department of Civil Engineering, Dalian Maritime University, Dalian 116026, China School of Civil Engineering, Shenyang Jianzhu University, Shenyang 110168, China School of Civil and ...
متن کاملMoment-rotation response of nominally pinned beam-to-column joints for frames of pultruded fibre reinforced polymer
This paper presents the test results to characterise the moment-rotation response of nominally pinned joints in frames of pultruded shapes. Mimicking conventional steel construction the major-axis beamto-column joints are formed using pultruded FRP web cleats having steel bolting. There are two joint configurations with either a single row of three or two bolts per cleat leg. Testing is conduct...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Budownictwo i Architektura
سال: 2013
ISSN: 2544-3275,1899-0665
DOI: 10.35784/bud-arch.2140