Three different samples were synthesized based on polyepoxide resin, a solidifying agent, and Bi2O3 doping compound. The resin agent added in 2:1 ratio by weight the compound was ratios of 0, 5, 10 wt. %. density composites measured using an MH-300A densimeter with uncertainty measurement 0.001 g/cm3. measurements showed that fabricated composite varied from 1.103 g/cm3 to 1.20 when reinforcing raised 0 % Furthermore, γ-ray shielding parameters evaluated simulated mean track length γ-photons inside MCNP-5 code. results show enhancement parameter increasing concentration, where linear attenuation coefficient values increased 0.101 cm−1 0.118 as concentration increase LAC has positive effect other properties.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shielding of Gamma Radiation

In the discussion that follows, we assume that gamma rays are the radiation of interest. The principles discussed also apply to monoenergetic x rays; in many cases of concern in x-ray shielding, however, the photons are produced in the bremsstrahlung process that yields a wide and continuous distribution of photon energies. Specialized shielding approaches have been developed to carry out shiel...

متن کامل

Monte Carlo calculation of shielding properties of newly developed heavy concretes for megavoltage photon beam spectra used in radiation therapy

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and t...

متن کامل

Assessment of the Radiation Attenuation Properties of Several Lead Free Composites by Monte Carlo Simulation

Background:In diagnostic radiology lead apron, are usually used to protect patients and radiology staff against ionizing radiation. Lead apron is a desirable shield due to high absorption and effective attenuation of x-ray photons in the diagnostic radiology range.Objective: Although lead aprons have good radiation protection properties, in recent years, researchers have been looking for altern...

متن کامل

Monte Carlo Shielding Analysis Capabilities with Mavric

Monte Carlo shielding analysis capabilities in SCALE 6 are centered on the Consistent Adjoint Driven Importance Sampling (CADIS) methodology. CADIS is used to create an importance map for space/energy weight windows as well as a biased source distribution. New to SCALE 6 are the Monaco functional module, a multigroup fixed-source Monte Carlo transport code, and the Monaco with Automated Varianc...

متن کامل

Radiation shielding for gamma stereotactic radiosurgery units

Shielding calculations for gamma stereotactic radiosurgery units are complicated by the fact that the radiation is highly anisotropic. Shielding design for these devices is unique. Although manufacturers will answer questions about the data that they provide for shielding evaluation, they will not perform calculations for customers. More than 237 such units are now installed in centers worldwid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied sciences

سال: 2023

ISSN: ['2076-3417']

DOI: https://doi.org/10.3390/app13031757