More on calcium ion activity buffers for coagulation testing.
terpreted as postovulatory luteal phase rather than follicular. Assuming a 2.2 mg/L positive bias with SST, our current laboratory follicular phase progesterone reference range of ,1.6 mg/L could increase to ,3.8 mg/L with SST. We recommend that all progesterone serum samples be collected in plain glass tubes until this SST interference problem is resolved. Our laboratory has notified Roche Dia...
متن کاملIsocitrate as calcium ion activity buffer in coagulation assays.
BACKGROUND Ca(2+) activity close to the physiological concentration of 1.3 mmol/L is essential in blood coagulation. Is this also true for the performance of global diagnostic coagulation assays? We searched for compounds that would buffer Ca(2+) activity at approximately 1.3 mmol/L without disturbing coagulation reactions and investigated whether such Ca(2+) buffering improves diagnostic effic...
متن کاملHydrogen ion buffers and enzymatic activity: myosin B adenosinetriphosphatase.
The production of hydrogen ions during the hydrolysis of ATP by myosin B and the consequent fall in pH can produce alterations in enzymatic activity directly, or by influencing Ca ion concentrations controlled by metal-chelate systems. Adequate hydrogen ion buffer systems can limit pH changes to acceptable levels. However, several commonly used hydrogen ion buffers have been reported to have sp...
متن کاملCalcium ion-dependent p-nitrophenyl phosphate phosphatase activity and calcium ion-dependent adenosine triphosphatase activity from human erythrocyte membranes.
In the presence of ATP and of Mg(2+), human erythrocyte membranes show a phosphatase activity towards p-nitrophenyl phosphate which is activated by low concentrations of Ca(2+). The effect of Ca(2+) is strongly enhanced if either K(+) or Na(+) is also present. Activation of the p-nitrophenyl phosphate phosphatase by Ca(2+) reaches a half-maximum at about 8mum-Ca(2+) and is apparent only when th...
متن کاملCointegration: More on Testing Methods
An alternative to the Engle-Granger tests is the Cointegration Regression Durbin-Watson (CRDW) test of Sargan and Bhargava (1983). The test involves a simple regression of one variable on the other, and the standard Durbin-Watson test on the residuals. Recall the null for the DW test is that the residuals form a nonstationary random walk, whereas the alternative hypothesis is that the residuals...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry
سال: 1999
ISSN: 0009-9147,1530-8561
DOI: 10.1093/clinchem/45.9.1575