MRI simulator for instruction in pulse-sequence selection

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Basic Strategies for Body MRI: Pulse Sequence

The abdomen and pelvis present an ensemble of problems for MR imaging. 1. There is a problem of contrast; there are an almost infinite variety of disease processes that can occur in the abdomen/pelvis, and no one sequence is ideal for all. 2. There is the problem of signal-to-noise and coverage; evaluation of the abdomen/pelvis often requires a large field-of-view 3. There are problems with com...

متن کامل

Single shot three‐dimensional pulse sequence for hyperpolarized 13C MRI

PURPOSE Metabolic imaging with hyperpolarized 13 C-labeled cell substrates is a promising technique for imaging tissue metabolism in vivo. However, the transient nature of the hyperpolarization, and its depletion following excitation, limits the imaging time and the number of excitation pulses that can be used. We describe here a single-shot three-dimensional (3D) imaging sequence and demonstra...

متن کامل

the test for adverse selection in life insurance market: the case of mellat insurance company

انتخاب نامساعد یکی از مشکلات اساسی در صنعت بیمه است. که ابتدا در سال 1960، توسط روتشیلد واستیگلیتز مورد بحث ومطالعه قرار گرفت ازآن موقع تاکنون بسیاری از پژوهشگران مدل های مختلفی را برای تجزیه و تحلیل تقاضا برای صنعت بیمه عمر که تماما ناشی از عدم قطعیت در این صنعت میباشد انجام داده اند .وهدف از آن پیدا کردن شرایطی است که تحت آن شرایط انتخاب یا کنار گذاشتن یک بیمه گزار به نفع و یا زیان شرکت بیمه ...

15 صفحه اول

MRI based radiotherapy planning and pulse sequence optimization

Radiotherapy plays an increasingly important role in cancer treatment, and medical imaging plays an increasingly important role in radiotherapy. Magnetic resonance imaging (MRI) is poised to be a major component in the development towards more e ective radiotherapy treatments with fewer side e ects. This thesis attempts to contribute in realizing this potential. Radiotherapy planning requires s...

متن کامل

Instruction Set Simulator In Embedded System

In embedded system design, there is an increasing demand for a cache simulation module inside a well-known instruction set simulator QEMU. System level, Algorithmic level, Instruction set level, Register-transfer level (RTL) simulation model can also be used for the synthesis of the embedded system. In embedded system design, there is an increasing demand for modeling techniques that can provid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: American Journal of Roentgenology

سال: 1986

ISSN: 0361-803X,1546-3141

DOI: 10.2214/ajr.147.1.199