Multicenter Comparison of Four Contemporary Sensitive Troponin Immunoassays
نویسندگان
چکیده
منابع مشابه
Multicenter comparison of automated procalcitonin immunoassays
OBJECTIVES A multicenter study to compare results of BRAHMS Kryptor PCT with those obtained using four BRAHMS-partnered procalcitonin (PCT) automated immunoassays (DiaSorin Liaison, BioMérieux Vidas, Roche Cobas E601 and Siemens Advia Centaur) and the Diazyme immunotubidimetric assay implemented on four clinical chemistry platforms (Abbott Architect c16000, Siemens Advia 2400, Roche Cobas C501 ...
متن کاملMulticenter Comparison of Seven 25OH Vitamin D Automated Immunoassays
BACKGROUND The measurement of 25OH vitamin D continues to grow in clinical laboratories. The aim of this multi-center study was to compare the results of seven automated commercial immunoassays with a reference HPLC technique. METHODS One hundred and twenty consecutive outpatient serum samples were centrifuged, divided in aliquots, frozen and shipped to the participating laboratories. 25OH Vi...
متن کاملNon-commutability of results of highly sensitive troponin I and T immunoassays
INTRODUCTION The measurement of cardiospecific troponins is pivotal in the diagnostic and prognostic approach of patients with suspected acute myocardial infarction (AMI). However, no information is available on the commutability of results between the novel highly-sensitive (HS) troponin T (TnT) and I (TnI) immunoassays. MATERIALS AND METHODS The study population consisted in 47 consecutive ...
متن کاملWill high-sensitive troponin immunoassays lead to more clarity or confusion in clinical practice?
Although increases in cTnI (cardiac troponin I) and cTnT (cardiac troponin T) always indicate myocardial damage, the test is not able to identify the mechanisms responsible for this damage, which may not be due to ischaemia, but rather to other clinical conditions. In the present issue of Clinical Science, Filusch and co-workers have assessed cTnT using a high-sensitive assay in patients with p...
متن کاملMulticenter Analytical Validation of Aβ40 Immunoassays
BACKGROUND Before implementation in clinical practice, biomarker assays need to be thoroughly analytically validated. There is currently a strong interest in implementation of the ratio of amyloid-β peptide 1-42 and 1-40 (Aβ42/Aβ40) in clinical routine. Therefore, in this study, we compared the analytical performance of six assays detecting Aβ40 in cerebrospinal fluid (CSF) in six laboratories ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Medical Biochemistry
سال: 2014
ISSN: 1452-8266,1452-8258
DOI: 10.2478/jomb-2014-0015