Multielement position sensitive proportional counter for measurement of tritium labeled gas movement.
نویسندگان
چکیده
منابع مشابه
The C.A.T. Pixel Proportional Gas Counter Detector
A simple geometry of real pixel gas detectors has been evaluated that circumvents the limitations of a microstrips, namely aging, gain drift and flux limitation due to the dielectric charging. A good resolution has been obtained while preserving a large active size and a high gain and counting rate capabilities.
متن کاملDevelopment and performance of a position-sensitive proportional avalanche counter tracking system
Most of our current understanding in nuclear physics has come from using stable targets and beams. Stable nuclei represent only a small fraction of the total nuclei that can exist, but do not exhibit many of the exotic proprieties seen in nuclei far from stability, such as halos [1]. The ability to study unstable nuclei has opened up a vast new range of physics to be explored. The decay of thes...
متن کاملThe gas proportional scintillation counter / microstrip gas chamber hybrid detector
The gas proportional scintillation counter/microstrip gas chamber (GPSC/MSGC) hybrid detector for X-ray spectrometry is described. The detector uses a CsI-coated microstrip plate placed in direct contact with the gas-filling as the photosensor readout for the GPSC scintillation substituting for the photomultiplier tube (PMT). Usable photosensor maximum gain is limited by optical positive feedba...
متن کاملDemonstration of axonal flow by the movement of tritium-labeled protein in mature optic nerve fibers.
* This work has been supported by grants from the U.S. Department of the Interior, Office of Saline Water, and the National Research Council of Canada. t Alfred P. Sloan Foundation fellow. 1 Rowlinson, J. S., Mol. Phys., 7, 349 (1964); ibid., 8, 107 (1964). 2Henderson, D., and S. G. Davison, these PROCEEDINGS, 54, 21 (1965). 3 Hill, T. L., Statistical Mechanics (New York: McGraw-Hill, 1956). 4R...
متن کاملPurification of tritium-labeled cholera toxin.
Cholera toxin was labeled with tritium by the Wilzbach technique, and highly purified radiolabeled toxin was obtained by Sephadex column chromatography and disc gel electrophoresis. 3H-labeled cholera toxin retained its biological activity and chemical stability and had a specific activity of 405.9 muCi/mumol. The methods utilized in extraction and purification of 3H-labeled toxin may be advant...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Nuclear Science and Technology
سال: 1988
ISSN: 1881-1248,0022-3131
DOI: 10.3327/jnst.25.341