Multifocal Electroretinography as a Method of Functional Assessment of Retinal Laser Injury in Experimental Studies

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the effectiveness of strategy-based instruction in teaching english as a second or foreign language: a meta-analysis of experimental studies

a large number of single research studies on the effects of strategy-based instruction (sbi) in teaching english as a foreign or second language has been conducted so far. however, the lack of a comprehensive meta-analysis targeting the effectiveness of english language sbi is observed. moreover, the findings of experimental studies regarding the context of the english language, proficiency lev...

Noninvasive assessment of retinal function in rats using multifocal electroretinography.

PURPOSE To assess the applicability of multifocal electroretinograms (mfERGs) for evaluation of function in this small-eyed animal with a rod-dominant retina that is often used to model retinal diseases. METHODS Noninvasive monocular mfERGs were recorded in anesthetized albino (Sprague-Dawley) and pigmented (Long Evans) rats. Achromatic stimuli subtending a 49 degrees by 53 degrees field cons...

متن کامل

multifocal electroretinography in the assessment of eyes with central retinal vein occlusion

data suggest that the multifocal electroretinography (mferg) may have a role in the assessment of patients with central retinal vein occlusion (crvo). to explore the mferg responses in patients with crvo. mferg responses were recorded at 61 discrete retinal locations from both eyes of 25 patients diagnosed with retinal vein occlusions within 3 weeks of onset. the latencies and amplitudes of ave...

متن کامل

The use of multifocal electroretinography in the assessment of retinal toxicity caused by pharmacological agents

Multifocal electroretinography (mfERG) was developed by Sutter and Tran1 and has since revolutionized objective functional assessment of retinal diseases. In contrast to full-field electroretinography (ERG), which measures the electrical activity of the entire retina, mfERG allows simultaneous measurements of multiple responses at different retinal locations, thus enabling topographic mapping o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Ophthalmology in Russia

سال: 2021

ISSN: 2500-0845,1816-5095

DOI: 10.18008/1816-5095-2021-1-110-116