Multiple energy extraction reduces beam delivery time for a synchrotron-based proton spot-scanning system
نویسندگان
چکیده
منابع مشابه
Modelling of a proton spot scanning system using MCNP6
The aim of this work was to model the characteristics of a clinical proton spot scanning beam using Monte Carlo simulations with the code MCNP6. The proton beam was defined using parameters obtained from beam commissioning at the Skandion Clinic, Uppsala, Sweden. Simulations were evaluated against measurements for proton energies between 60 and 226 MeV with regard to range in water, lateral spo...
متن کاملA Proton Beam Therapy System Dedicated to Spot-Scanning Increases Accuracy with Moving Tumors by Real-Time Imaging and Gating and Reduces Equipment Size
PURPOSE A proton beam therapy (PBT) system has been designed which dedicates to spot-scanning and has a gating function employing the fluoroscopy-based real-time-imaging of internal fiducial markers near tumors. The dose distribution and treatment time of the newly designed real-time-image gated, spot-scanning proton beam therapy (RGPT) were compared with free-breathing spot-scanning proton bea...
متن کاملCyclotron versus Synchrotron for Proton Beam Therapy
Two categories in the beam delivery system of proton therapy, scattering and scanning, are closely related to the temporal beam structure, in turn, type of accelerators. Since the synchrotron is well matured technically, efficient and dependable routine operation will be achieved if it is combined with a scatterer system. \Vhen more sophisticated scanning system is sought for better dose distri...
متن کاملProspective study to evaluate the safety of the world-first spot-scanning dedicated, small 360-degree gantry, synchrotron-based proton beam therapy system
This is a report of a single-institution prospective study evaluating the safety of a spot-scanning dedicated, small 360-degree gantry, synchrotron-based proton beam therapy (PBT) system. Data collection was performed for 56 patients with 59 treatment sites who received proton beam therapy at Hokkaido University Hospital between March 2014 and July 2015. Forty-one patients were male and 15 were...
متن کاملPerformance characterization of a 3D liquid scintillation detector for discrete spot scanning proton beam systems.
Existing systems for proton beam dosimetry are limited in their ability to provide a complete, accurate, and detailed account of volumetric dose distribution. In this work, we describe the design and development of a portable, fast, and reusable liquid scintillator-based three-dimensional (3D) optical detection system for use in proton therapy. Our long-term goal is to use this system clinicall...