Multiresolution iterative reconstruction in high-resolution extremity cone-beam CT

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Iterative reconstruction optimisations for high angle cone-beam micro-CT

We address several acquisition questions that have arisen for the high cone-angle helical-scanning micro-CT facility developed at the Australian National University. These challenges are generally known in medical and industrial cone-beam scanners but can be neglected in these systems. For our large datasets, with more than 2048 voxels, minimising the number of operations (or iterations) is cru...

متن کامل

Combining Analytical and Iterative Reconstruction in Helical Cone-Beam CT

Contemporary algorithms employed for reconstruction of 3D volumes from helical cone beam projections are so called non-exact algorithms. This means that the reconstructed volumes contain artifacts irrespective of the detector resolution and number of projection angles employed in the process. In this thesis, three iterative schemes for suppression of these so called cone artifacts are investiga...

متن کامل

High-Performance Soft-Tissue Imaging in Extremity Cone-Beam CT.

PURPOSE Clinical performance studies of an extremity cone-beam CT (CBCT) system indicate excellent bone visualization, but point to the need for improvement of soft-tissue image quality. To this end, a rapid Monte Carlo (MC) scatter correction is proposed, and Penalized Likelihood (PL) reconstruction is evaluated for noise management. METHODS The accelerated MC scatter correction involved fas...

متن کامل

Cache-Aware GPU Optimization for Out-of-Core Cone Beam CT Reconstruction of High-Resolution Volumes

This paper proposes a cache-aware optimization method to accelerate out-of-core cone beam computed tomography reconstruction on a graphics processing unit (GPU) device. Our proposed method extends a previous method by increasing the cache hit rate so as to speed up the reconstruction of high-resolution volumes that exceed the capacity of device memory. More specifically, our approach accelerate...

متن کامل

High-resolution helical cone-beam micro-CT with theoretically-exact reconstruction from experimental data.

PURPOSE In this paper we show that optimization-based autofocus may be used to overcome the instabilities that have, until now, made high-resolution theoretically-exact tomographic reconstruction impractical. To our knowledge, this represents the first successful use of theoretically-exact reconstruction in helical micro computed tomography (micro-CT) imaging. We show that autofocus-corrected, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physics in Medicine and Biology

سال: 2016

ISSN: 0031-9155,1361-6560

DOI: 10.1088/0031-9155/61/20/7263