Multislice double inversion pulse sequence for efficient black-blood MRI

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-selective double inversion recovery pre-pulse for flow-independent black blood myocardial viability imaging

Introduction & Purpose: MRI late gadolinium enhancement (LGE) using the inversion-recovery (IR) sequence is the current gold standard for the assessment of myocardial viability. Although it achieves high contrast between infarct and normal myocardium, there is often poor infarct-to-blood contrast. Flow-dependent and diffusion-prepared black-blood LGE techniques have previously been described. T...

متن کامل

Improved fat water separation with water selective inversion pulse for inversion recovery-based cardiac MRI sequence

Background Chemical shift based water-fat separation methods can be used to reconstruct simultaneous fat and water images, thereby improving the sensitivity of fat detection using a positive fat contrast. The presence of fatty infiltration is a hallmark pathological feature of arrhythmogenic right ventricular cardiomyopathy (ARVC). Furthermore, the presence of fatty infiltration in chronic myoc...

متن کامل

Feasibility of multi-slice black-blood double inversion-recovery imaging

TI(N), SNR in CA f P for SNR in CA as SI(N)ISI(l) in ms SD compared to N=l muscle 691 1.36*0.17 1 469 1.393~ 0.24 0.34 0.91 346 1.39+0.29 0.62 0.82 272 1.46f0.21 0.10 0.75 224 1.47i0.23 0.06 0.68 190 1.45+0.24 0.11 0.64 A multi-slice acquisition technique was proposed for double inversionrecovery (DIR) black-blood imaging. The method utilizes short inversion time providing an acquisition of sev...

متن کامل

Basic Strategies for Body MRI: Pulse Sequence

The abdomen and pelvis present an ensemble of problems for MR imaging. 1. There is a problem of contrast; there are an almost infinite variety of disease processes that can occur in the abdomen/pelvis, and no one sequence is ideal for all. 2. There is the problem of signal-to-noise and coverage; evaluation of the abdomen/pelvis often requires a large field-of-view 3. There are problems with com...

متن کامل

EPISTAR MRI: multislice mapping of cerebral blood flow.

A method is described for multislice EPISTAR that perfectly compensates magnetization transfer effects. Inflowing arterial spins are labeled with a 360 degrees adiabatic pulse. Two control tags are applied sequentially at the same location as the labeling pulse, each with a 180 degrees adiabatic pulse so the total RF irradiation, frequency shift, and bandwidth of the labeling and control pulses...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2002

ISSN: 0740-3194,1522-2594

DOI: 10.1002/mrm.10094