Multiwire shielded cable parameter computation
نویسندگان
چکیده
منابع مشابه
Computation of Electrostatic and Gravitational Sag in MultiWire Chambers
A numerical method of determining the wire sag in a multiwire proportional chamber used in RICH [1] by solving the second order differential equation which governs the wire stability has been presented. The three point Finite Difference Method (FDM) has generated a tridiagonal matrix equation relating the deflection of wire segments to the force acting on it. The precise estimates of electrosta...
متن کاملMultiwire Differential Signaling
This document describes and discloses a set of ideas for improving the bandwidth on a signaling system composed of more than one wire. These ideas represent a generalization of practiced 2-wire differential signaling, widely used in computer and communications systems. The central notion is to group a set of N wires together (N > 2), allowing more than one symbol to be transmitted on the wire-s...
متن کاملShielded Cable Transfer Impedance Measurements High frequency range 100 MHz–1 GHz
©2011 IEEE Plotting the individual components is shown in Fig. 11. Adding the pulses gives the solution for V 10, t 2 shown in Fig. 12. All of the results of the above examples were validated using the PSPICE circuit analysis computer program. Use of the exact lossless transmission line model in PSPICE for more complicated lossless transmission-line problems is highly recommended [1]. VI. Refer...
متن کاملA distributed parameter identification problem in neuronal cable theory models.
Dendritic and axonal processes of nerve cells, along with the soma itself, have membranes with spatially distributed densities of ionic channels of various kinds. These ionic channels play a major role in characterizing the types of excitable responses expected of the cell type. These densities are usually represented as constant parameters in neural models because of the difficulty in experime...
متن کاملMultiwire proportional chambers in the HERMESexperimentA
The multiwire proportional chambers of the HERMES spectrometer are described. The chambers are located in the spectrometer magnet gap which imposed strong constraints on their design. Non-ammable gas mixture of Ar(65%), CO 2 (30%) and CF 4 (5%) is successfully used with an eeciency plateau 500V wide. The readout is performed by means of the recently developed LeCroy PCOS4 acquisition system upg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Magnetics
سال: 1995
ISSN: 0018-9464
DOI: 10.1109/20.376350